Dimension One Spas Sarena Bay manual Filter Cycle Start Time, Filter Cycle Duration, Pump Run Time

Page 35
Filter Cycle Start Time

2003 Sarena Bay

Export Owner’s Manual

Button in the same manner as the hour number. When the desired number is displayed, push the LIGHT Button to accept the selection and change the flashing number to a flashing AM or PM indicator. Adjust the indicator with the UP or DOWN Buttons. After reaching the correct time, push the PROGRAM Button to set the time and exit the time setting mode. You will then be prompted to set the filter start time.

Filter Cycle Start Time

After setting the time-of-day, the top line of the Digital Display Window will read “SET FILTER CYCLE TIME”. Push the UP or DOWN Buttons in the same manner as setting the clock to select the time you want your filter cycle to start. When your desired filter cycle start time is set in the display, push the PROGRAM Button to continue. The pre-set factory default is 12:00 p.m. to 1:00 p.m. repeating every 12 hours unless the number of filter cycles per day has been changed.

Keep in mind that you will later be prompted to set the filter cycle duration and the number of filter cycles. Be sure to keep this in mind when programming your filter cycle start time.

Note

During a filter cycle, the bottom left of the Digital Display Window will read “SPA FILTERING”. During the filter cycle, JETS 1 will activate, the first 5 minutes at high speed and the remainder of the filter cycle time at low speed. JETS 2 will also activate for 1 minute on high speed and then turn off.

Filter Cycle Duration

After setting the filter cycle start time, the top line of the Digital Display Window will read “SET CYCLE DURATION”. Push the UP or DOWN Buttons to toggle between 10, 20, 30, 40, 50, or 60 minutes. The filter cycle will be at low speed. When your desired filter cycle length appears in the Digital Display Window, push the PROGRAM Button to select it. The pre-set factory default is 20 minutes.

Number of Filter Cycles

After setting the length of the filter cycle, you will be prompted to set the number of filter cycles. The top line of the Digital Display Window will read “SET # OF CYCLES”. Push the UP or DOWN Button to toggle between 1, 2, 3, or 4 cycles per day. When your desired number of cycles appears on the Digital Display Window, push the PROGRAM Button to select it. The pre-set factory default is 1 cycles per day.

Long and/or numerous filter cycles could cause overheating of the hot tub - especially in hot climates.

Caution

Pump Run Time

After setting the number of filter cycles, the top line of the Digital Display Window will read “SET PUMP RUN TIME”. Push the UP or DOWN Button to toggle between 30, 45 and 60 minutes. This sets the length of time the pump will run when a jets Button is pushed. For example, if you choose 45 minutes, when you push a jets Button, the pump will run for 45 minutes before shutting down automatically. When your desired pump run time appears on the Digital Display Window push the PROGRAM Button to select it. The pre-set factory default is 30 minutes.

29

Image 35
Contents Page 2003 Sarena Bay Export Owner’s Manual Export Owner’s Manual Table of ContentsPERSONAL THERAPY CONTROL PATENT PENDING SWITCHES HYDROSPORT AQUATIC FITNESS GEAR OPTIONALExport Owner’s Manual USING THE TOP SIDE CONTROLSADJUSTING THE FOUNTAIN 2003 Sarena BaySPECIAL COLD WEATHER INSTRUCTIONS 2003 Sarena Bay Export Owner’s Manual READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY Safety FirstIMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYTo Reduce the Risk of Injury Hyperthermia DON’T allow horseplay or unsupervised use of your Sarena Bay Do’s and Don’tsDon’t DON’T block or sit on the filter recess areaDimension One Spas 2611 Business Park Drive Vista, CA 760 Warning SignsFountain Sarena Bay FeaturesPersonal Therapy Control Patent Pending Switches Dynamic LED Underwater LightingInnovative Seating - For Revolutionary Design Features“No-float” angles Upright position Multiple Lounges Accommodate BioForm ReclinersBio-Wall / Bench Seat Pivot featurePivot Seat Bench Seatthe front part of the upper and lower Frontal Therapy SeatSport Zone Seat jetsScrolling Message Center section Additional Design FeaturesTop Side Control Synchronous Spa Lights PTC SwitchesDynamic Massage Sequencer FountainSoft Tile Pillow Weir Basket / SkimmerHydroSport / OptiMounts Remotely Control The Sarena Bay NeckFlex Jet PillowJet System Selector Valve InfraRed SensorLoad Sharing UltraPure Water Management SystemVision Smart HeatSonic Immersion System SIS Optional D1 Remote Control OptionalHydroSport Aquatic Fitness Gear Optional Initial Startup Weir Skimmer/Filter 2003 Sarena Bay Export Owner’s Manual 2003 Sarena Bay Export Owner’s Manual Scrolling Message Center Using The Top Side ControlsOperation Feature JETS 1&2 ButtonJet Pump 3 Button Water Feature Button Up / Down Buttons PROGRAM Button Light / Enter ButtonScrolling Message Center Messages Heat Status Light Dimension One Spas ICON Logo→Rinse Filters Clean Filters Overheat DO NOT ENTER THE WATER when “OVERHEAT” is displayed onChange Water Change Vision Cartridge Spa Check UpCooling Flashing Display and/or “Check Water Level”Erroneous Temperature on the Display Ice Summer Mode Standby Mode Setting the TimeProgramming the Scrolling Message Center Pump Run Time Filter Cycle Start TimeFilter Cycle Duration Number of Filter CyclesDigital Display Window Invert Temperature Unit SelectionVision Cartridge Waterfall Run TimeProgramming Unlock Control Panel ResetProgramming Lock JETS Button Dynamic Massage SequencerControl Panel Description LIGHT ButtonMassage Zones SPEED ButtonBEGIN/PAUSE Button SEQUENCE ButtonZone C Massage Zone DescriptionZone A Zone BOperating the Dynamic Massage Sequencer Zone FJet System Selector Valve Adjusting the FountainAdjusting Water Flow Standard VCR Jets→ - Rotator Adjustable and Interchangeable JetsStandard VCR Jets→ - Directional Euro Jets - Directional Mini VCR Jets→ - RotatorMini VCR Jets→ - Directional a Mini VCR Jets→- RotatorDraining Your Equipment Routine Equipment MaintenanceFilter Cleaning Ultralife→ Shell Light Bulb ReplacementSurface Care Items Required for Winterizing Dimension One “ EnviroTect” Skirts and Vinyl CoversSpecial Cold Weather Instructions Care for the Wood Spa CabinetProcedure for Winterizing Spring Time Startup Warranty Service Information Definition Glossary of TermsTerm Pump Heating System Troubleshooting GuideSymptom ProblemWater System Electrical System Cont2003 Sarena Bay Export Owner’s Manual 2003 Sarena Bay Export Owner’s Manual