Dimension One Spas Sarena Bay manual Programming Lock, Programming Unlock, Control Panel Reset

Page 37

2003 Sarena Bay

Export Owner’s Manual

Programming Lock

The programming lock is to prevent unauthorized programming and water temperature adjustments. When the programming lock is engaged, all programmed or default functions will operate normally. Also, the hot tub user may operate the pumps, the hot tub light or view the time-of-day, but no programming changes may be made. When the programming lock is enabled, the Digital Display Window will scroll “PROGRAMMING LOCKED” twice on the lower left side of the display, then a lock icon will be displayed on the right side of the Digital Display Window To enable the programming lock, all the following buttons must be pushed within

3seconds:

1.Push the Dimension One Spas ICON (logo)Button.

2.Push the Dimension One Spas ICON (logo)Button.

3.Push the PROGRAM Button.

Programming Unlock

To unlock the Panel: The following buttons must be pushed within 3 seconds:

1.Push the ENTER Button.

2.Push the ENTER Button.

3.Push the Dimension One Spas ICON (logo)Button. When the last Button is pushed all buttons will be active.

Control Panel Reset

This function is used to completely reset the clock and all other system variables to the factory defaults. Please keep in mind that this resets all maintenance messages (clean filters, change water, etc.) as if the hot tub is being installed the day of the panel reset. To reset the control system all of the following buttons must be pushed within 3 seconds:

1.Push the ICON (logo) Button

2.Push the ENTER Button

3.Push the PROGRAM Button

The top line of the Digital Display Window will read “RESET PROGRAMMING?” The bottom line of the Digital Display Window will read “IF SO, PUSH ICON

4.Push the Dimension One ICON Button to reset the entire control system to factory defaults or do not touch a button for 10 seconds to exit.

31

Image 37
Contents Page 2003 Sarena Bay Export Owner’s Manual PERSONAL THERAPY CONTROL PATENT PENDING SWITCHES Table of ContentsHYDROSPORT AQUATIC FITNESS GEAR OPTIONAL Export Owner’s ManualADJUSTING THE FOUNTAIN USING THE TOP SIDE CONTROLS2003 Sarena Bay Export Owner’s ManualSPECIAL COLD WEATHER INSTRUCTIONS 2003 Sarena Bay Export Owner’s Manual IMPORTANT SAFETY INSTRUCTIONS Safety FirstREAD AND FOLLOW ALL INSTRUCTIONS CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYTo Reduce the Risk of Injury Hyperthermia Don’t Do’s and Don’tsDON’T block or sit on the filter recess area DON’T allow horseplay or unsupervised use of your Sarena BayDimension One Spas 2611 Business Park Drive Vista, CA 760 Warning SignsPersonal Therapy Control Patent Pending Switches Sarena Bay FeaturesDynamic LED Underwater Lighting FountainInnovative Seating - For Revolutionary Design FeaturesBio-Wall / Bench Seat BioForm ReclinersPivot feature “No-float” angles Upright position Multiple Lounges AccommodatePivot Seat Bench SeatSport Zone Seat Frontal Therapy Seatjets the front part of the upper and lowerTop Side Control Additional Design FeaturesScrolling Message Center section Dynamic Massage Sequencer PTC SwitchesFountain Synchronous Spa LightsHydroSport / OptiMounts Weir Basket / SkimmerSoft Tile Pillow Jet System Selector Valve NeckFlex Jet PillowInfraRed Sensor Remotely Control The Sarena BayVision UltraPure Water Management SystemSmart Heat Load SharingHydroSport Aquatic Fitness Gear Optional D1 Remote Control OptionalSonic Immersion System SIS Optional Initial Startup Weir Skimmer/Filter 2003 Sarena Bay Export Owner’s Manual 2003 Sarena Bay Export Owner’s Manual Operation Using The Top Side ControlsScrolling Message Center Jet Pump 3 Button JETS 1&2 ButtonFeature Water Feature Button Up / Down Buttons PROGRAM Button Light / Enter ButtonRinse Filters Clean Filters Heat Status Light Dimension One Spas ICON Logo→Scrolling Message Center Messages Change Water Change Vision Cartridge DO NOT ENTER THE WATER when “OVERHEAT” is displayed onSpa Check Up OverheatErroneous Temperature on the Display Ice Flashing Display and/or “Check Water Level”Cooling Programming the Scrolling Message Center Setting the TimeSummer Mode Standby Mode Filter Cycle Duration Filter Cycle Start TimeNumber of Filter Cycles Pump Run TimeVision Cartridge Temperature Unit SelectionWaterfall Run Time Digital Display Window InvertProgramming Lock Control Panel ResetProgramming Unlock Control Panel Description Dynamic Massage SequencerLIGHT Button JETS ButtonBEGIN/PAUSE Button SPEED ButtonSEQUENCE Button Massage ZonesZone A Massage Zone DescriptionZone B Zone COperating the Dynamic Massage Sequencer Zone FAdjusting Water Flow Adjusting the FountainJet System Selector Valve Standard VCR Jets→ - Directional Adjustable and Interchangeable JetsStandard VCR Jets→ - Rotator Mini VCR Jets→ - Directional Mini VCR Jets→ - Rotatora Mini VCR Jets→- Rotator Euro Jets - DirectionalFilter Cleaning Routine Equipment MaintenanceDraining Your Equipment Surface Care Light Bulb ReplacementUltralife→ Shell Special Cold Weather Instructions Dimension One “ EnviroTect” Skirts and Vinyl CoversCare for the Wood Spa Cabinet Items Required for WinterizingProcedure for Winterizing Spring Time Startup Warranty Service Information Term Glossary of TermsDefinition Pump Symptom Troubleshooting GuideProblem Heating SystemWater System Electrical System Cont2003 Sarena Bay Export Owner’s Manual 2003 Sarena Bay Export Owner’s Manual