Dimension One Spas Sarena Bay manual Routine Equipment Maintenance, Draining Your Equipment

Page 45
Routine Equipment Maintenance

2003 Sarena Bay

Export Owner’s Manual

Routine Equipment Maintenance

Draining Your Equipment

Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use this system unless they are supervised at all times.

Danger

All models are gravity drained. Do not drain water onto your lawn or plants unless all of the bromine or chlorine has dissipated from the water. The sanitizer in your water will dissipate quickly by leaving the cover off and exposing the water to direct sunlight. Drain and replace your water every six months. For heavy water use, you may wish to change the water more frequently.

You may purchase an optional submersible pump from your dealer or from our Virtual Showroom at www.d1spas.com to provide quicker drainage.

Feature

Filter Cleaning

Before cleaning the filter element(s) place the spa in the “Standby” mode by pressing the Dimension One Spas ICON logofor 5 seconds. Your system is equipped with two top access filter cartridges. We recommend that you clean the filters every month as preventative maintenance.

To clean the skimmer filter cartridge, lift the center float of the skimmer assembly until it is fully extended. Hold the centerpiece of the assembly and turn it counterclockwise until the flats of the basket are aligned with the securing tabs. Then pull the basket assembly straight up to remove. Next, remove the E-Z Lock Filter cartridge by twisting the cartridge 1/4 turn counterclockwise to its stop. (Be careful not to overturn the filter) Then lift the filter out of its canister. Clean the cartridge with a high-pressure garden hose. Every other cleaning, soak the cartridges in a filter-cleaning solution, rinse it thoroughly, and reinstall. Replace the skimmer basket assembly and the access lid or cover. Exit the “Standby” mode by pressing Dimension Spas ICON logofor 5 seconds. After cleaning, run the pump for a few minutes at high speed, then return to the heating mode.

To clean the UltraPure™ filter cartridge, remove the E-Z Lock Filter cartridge by twisting the cartridge ¼ turn counterclockwise to its stop. Then lift the filter out of its canister. Clean the cartridge with a high- pressure garden hose. Every other cleaning, soak the cartridge in Dimension One Spas’ Cartridge Cleaner, then rinse it thoroughly, and reinstall. Replace the access lid or cover. Exit the “Standby” mode by pressing Dimension Spas ICON logofor 5 seconds.

39

Image 45
Contents Page 2003 Sarena Bay Export Owner’s Manual PERSONAL THERAPY CONTROL PATENT PENDING SWITCHES Table of ContentsHYDROSPORT AQUATIC FITNESS GEAR OPTIONAL Export Owner’s ManualADJUSTING THE FOUNTAIN USING THE TOP SIDE CONTROLS2003 Sarena Bay Export Owner’s ManualSPECIAL COLD WEATHER INSTRUCTIONS 2003 Sarena Bay Export Owner’s Manual IMPORTANT SAFETY INSTRUCTIONS Safety FirstREAD AND FOLLOW ALL INSTRUCTIONS CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYTo Reduce the Risk of Injury Hyperthermia Don’t Do’s and Don’tsDON’T block or sit on the filter recess area DON’T allow horseplay or unsupervised use of your Sarena BayDimension One Spas 2611 Business Park Drive Vista, CA 760 Warning SignsPersonal Therapy Control Patent Pending Switches Sarena Bay FeaturesDynamic LED Underwater Lighting FountainInnovative Seating - For Revolutionary Design FeaturesBio-Wall / Bench Seat BioForm ReclinersPivot feature “No-float” angles Upright position Multiple Lounges AccommodatePivot Seat Bench SeatSport Zone Seat Frontal Therapy Seatjets the front part of the upper and lowerAdditional Design Features Top Side ControlScrolling Message Center section Dynamic Massage Sequencer PTC SwitchesFountain Synchronous Spa LightsWeir Basket / Skimmer HydroSport / OptiMountsSoft Tile Pillow Jet System Selector Valve NeckFlex Jet PillowInfraRed Sensor Remotely Control The Sarena BayVision UltraPure Water Management SystemSmart Heat Load SharingD1 Remote Control Optional HydroSport Aquatic Fitness Gear OptionalSonic Immersion System SIS Optional Initial Startup Weir Skimmer/Filter 2003 Sarena Bay Export Owner’s Manual 2003 Sarena Bay Export Owner’s Manual Using The Top Side Controls OperationScrolling Message Center JETS 1&2 Button Jet Pump 3 ButtonFeature Water Feature Button Up / Down Buttons PROGRAM Button Light / Enter ButtonHeat Status Light Dimension One Spas ICON Logo→ Rinse Filters Clean FiltersScrolling Message Center Messages Change Water Change Vision Cartridge DO NOT ENTER THE WATER when “OVERHEAT” is displayed onSpa Check Up OverheatFlashing Display and/or “Check Water Level” Erroneous Temperature on the Display IceCooling Setting the Time Programming the Scrolling Message CenterSummer Mode Standby Mode Filter Cycle Duration Filter Cycle Start TimeNumber of Filter Cycles Pump Run TimeVision Cartridge Temperature Unit SelectionWaterfall Run Time Digital Display Window InvertControl Panel Reset Programming LockProgramming Unlock Control Panel Description Dynamic Massage SequencerLIGHT Button JETS ButtonBEGIN/PAUSE Button SPEED ButtonSEQUENCE Button Massage ZonesZone A Massage Zone DescriptionZone B Zone COperating the Dynamic Massage Sequencer Zone FAdjusting the Fountain Adjusting Water FlowJet System Selector Valve Adjustable and Interchangeable Jets Standard VCR Jets→ - DirectionalStandard VCR Jets→ - Rotator Mini VCR Jets→ - Directional Mini VCR Jets→ - Rotatora Mini VCR Jets→- Rotator Euro Jets - DirectionalRoutine Equipment Maintenance Filter CleaningDraining Your Equipment Light Bulb Replacement Surface CareUltralife→ Shell Special Cold Weather Instructions Dimension One “ EnviroTect” Skirts and Vinyl CoversCare for the Wood Spa Cabinet Items Required for WinterizingProcedure for Winterizing Spring Time Startup Warranty Service Information Glossary of Terms TermDefinition Pump Symptom Troubleshooting GuideProblem Heating SystemWater System Electrical System Cont2003 Sarena Bay Export Owner’s Manual 2003 Sarena Bay Export Owner’s Manual