Aruba Spa Hot Tub Models 2003 owner manual Trouble Shooting Guide, Problem Diagnosis Action

Page 37

TROUBLE SHOOTING GUIDE

PROBLEM • DIAGNOSIS • ACTION

P:Spa won’t turn on

D:No power in spa A1: Check Breaker

A2: Check Fuses

P:Spa comes on by itself

D:Normal function of heating and filtering

A:No action required

P:Pump shuts down unexpectedly while in use

D:Default timer of 20 minutes in the electronic operating system

A:Reactivate by touching desired button

P:Spa does not heat

D:Temperature setting is too low

A:Turn up thermostat

P:Poor jet action

D:Dirty filter

A:Clean filter

D:Air lock in pump

A:Loosen end pump union to release air

D:Water level too low

A:Fill spa

P:Spa light is out

D:Burned out bulb

A:Replace bulb

(The Light housing is located behind the spa pack, and there is no need to drain the spa to change the light bulb.)

36

Image 37
Contents Aruba Spas Dear Aruba Customer IntroductionHOW Your Aruba SPA is Built Getting Started Items Required for Installation of Your SPA Tools Required for InstallationImportant Safety Instructions Special Cold Weather Start UP Preparations Positioning Your SPAIndoor Installation Deck Installation Yard InstallationImportant Safety Instructions Electrical Connection AccessElectrical Connection START-UP Preparations SPA Pack Only turn union one turn Counter clockwise Initial START-UPSPA Operations Guide Light or LED Pump buttonFilter Cycle Programming Setting Water Temperature Micro Directional Hydrotherapy JetsMassage Jet Cluster JetsSwirl Jet Trouble Shooting Problem has Been Detected Pressure SwitchJET Blower System OzonatorsAqua Pure Water System Circulation PumpAqua Pure Water System cont’d Chemical Maintenance Initial Start UP Procedures Conducting Proper Water Tests Water Maintenance ScheduleWeekly Bromine Problems Associated with Improper Water Balance Chemical Table Equivalents ChartLow pH High pHDraining Your SPA Care for Your SPACauses of pH change To drain the spaSPA Surface Filter CleaningCover CabinetPage Special Cold Weather Instructions Warranty Information Warranty Page Problem Diagnosis Action Trouble Shooting GuideEye or skin irritation PH is too low Weekly Maintenance Schedule Division Leathead Road Kelowna, BC V1X 2J8