Aruba Spa 2003 Breeze, 2003 Escape, 2003 Serenade manual Trouble Shooting

Page 19
TROUBLE SHOOTING

TROUBLE SHOOTING

This is a self-diagnostic control system. The system will automatically display an alphanumeric symbol if a problem is detected.

No display at topside

-Check that the topside is correctly plugged into spa pack.

-Check the breaker

-Check that connection to main board is clean and sound

Display flashes "th1/39" on system start up

-Check that the temperature sensing probe connection to main board is clean and sound

Display flashes"th2/current temperature" on system start up

-Check that the temperature sensing probe connected to the main board is clean and sound

Note: a new temperature-sensing probe may be needed for the above 2 points.

Display flashes "th2/39" on system start up

- This indicates that both thermisters are detecting spa water temperature of less than 39° F/4° C or they are both disconnected (open). The pump will run in this condition.

Display flashes "OH" (OVER HEAT)

-This indicates that the spa water temperature is over 112° F. The system should shut down in this state and will re-start automatically when the water cools below 112° F

Display flashes "hot" (OVER HEAT)

-This indicates that the heater body is over 112° F. The system should shut down in this state and will re-start automatically when the water cools below 112° F.

Display flashes "HL" (HIGH LIMIT)

-This indicates that either the heater or the spa has reached 118° F or higher. The system will not re-start automatically. To re-start the system, the water temper- ature must be below 112° F and the heater key at the topside control must be pressed.

17

Image 19
Contents ARUBA SPAS Box 2266 Station R Kelowna, BC V1X 4K6 TABLE OF CONTENTS Dear Aruba Customer INTRODUCTIONHAZARD HOW YOUR ARUBA SPA IS BUILT GETTING STARTED ITEMS REQUIRED FOR THE INSTALLATION OF YOUR SPA TOOLS REQUIRED FOR INSTALLATIONusing your IMPORTANT SAFETY INSTRUCTIONSHAZARD these safetyDECK INSTALLATION YARD INSTALLATIONPOSITIONING YOUR SPA INDOOR INSTALLATION GND N L1 L2 ELECTRICAL CONNECTION ACCESSIMPORTANT SAFETY INSTRUCTIONS ELECTRICAL CONNECTIONDo not run the pump until the spa is full of START-UPPREPARATIONSPump INITIAL START-UPKnife Valve #1 Knife Valve #2a water temperature NO GREATER THAN This system should be set to maintain40 CELSIUS 104 F Invert Button SPA OPERATIONS GUIDETopside Control Component Identification Heat s and Heat t buttonsCELSIUS OR FAHRENHEIT Pump buttonLight Filter Cycle Programmingair flow may be restricted HYDROTHERAPY JETSMicro Directional All jet trim kits must be properly seated orMassage Jet Cluster JetsSwirl Jet This system only accepts a 220v Ozonator OZONATORS-OPTIONALIt is necessary to use Chlorine or Bromine chemical treatment with an ozonatorTROUBLE SHOOTING Display flashes FLO FLOW CHEMICAL MAINTENANCE INITIAL START UP PROCEDURES Sanitizers such as Sodium WATER MAINTENANCE SCHEDULECONDUCTING PROPER WATER TESTS WeeklyBROMINE High pH CHEMICAL TABLE OF EQUIVALENTS CHARTPROBLEMS ASSOCIATED WITH IMPROPER WATER BALANCE Low pHTo drain the spa CARE FOR YOUR SPADRAINING YOUR SPA Causes of pH changeat least once every six months FILTER CLEANINGSPA SURFACE Make sure you replace your filter cartridgescleaners CABINETCOVER When cleaning the surface use only acrylicFading and discolouration SPECIAL COLD WEATHER INSTRUCTIONS 1-877--877-2087 WARRANTY INFORMATIONand its exclusions For warranty service contact a Smart Protect Warranty service agent atL I M I T E D FIVE YEAR LIMITED NO LEAKONE YEAR LIMITED SKIRT WARRANTYREGISTRATION To validate this warranty, the original purchaser must complete the warranty registration card and mail it to ARUBA SPAS within 30 days of deliv- ery of the spa P Spa comes on by itself TROUBLE SHOOTING GUIDEPROBLEM DIAGNOSIS ACTION P Spa won’t turn onP Abnormal water usage P Water not cleanP Motor shuts down while in use P GFCI shuts down frequentlyP Scale deposits P pH is too lowP Formation of chloramines P Foaming of waterOptional Purchase CIRCULATION PUMP OPERATIONSDATE WEEKLY MAINTENANCE SCHEDULEClean Maintenance920 Leathead Road Kelowna, BC V1X 2J8