Circulation Pump | Clean up Cycle |
This is an optional feature. The circulation pump will | When the pump or blower is turned on by a button |
come on when the system is checking temperature, | press, a |
during filter cycles, during freeze conditions, or when | pump or blower is turned off or times out. The pump |
another pump is on. | and the ozone generator will run for one hour. |
17 Operating
Preset Filter Cycles
There are two filter cycles per day. The start and end times of each cycle are programmable. To program, set the time as instructed above, then press “MODE/ PROG” to advance to the next setting (or to exit after the last setting). The default filter cycles are as follows:
•The first filter cycle is automatically activated at
8:00 AM and operates the pump until 10:00 AM.
The “FILTER 1” indicator icon will light when filter
1is running.
•The second filter cycle is automatically activated at 8:00 PM and operates the pump until 10:00 PM.
The “FILTER 2” indicator icon will light when filter
2is running.
The pump and the ozone generator will run during filtration. At the start of each filter cycle, the blower will run on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run for five minutes. In the event of power loss or shut down, the time of day will need to be reset for filter cycles to run according to your desired programming.
Ozone
This is an optional feature. On most systems, the
ozone generator (if installed) runs during filter cycles
(except when pump 1 is operating at high speed on a
the pump runs. If your system is configured with the
optional ozone disable feature, the ozone generator will turn off for one hour any time a function button (“JETS 1”, “JETS 2”, “OPTION” etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 44°F within the heater, the pump automatically activates to provide freeze protection. The equipment stays on until four minutes after the sensors detect that the spa temperature has risen to 45°F or higher. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a
Your Spa