Cal Spas LTR20111000 manual Periodic Reminder Messages, Diagnostic Messages

Page 20

18

Operating SpaYour

Periodic Reminder Messages

Press the “Mode” button to reset a displayed reminder.

Message

Frequency

Action Required

rPH

Every 7 days

Test and adjust chemical levels per manufacturer’s instructions.

 

 

 

 

rSA

Every 7 days

Test and adjust chemical levels per manufacturer’s instructions.

 

 

 

 

rCL

Every 30 days

Remove, clean, and reinstall filter per manufacturer’s instructions.

 

 

 

 

rtg

Every 30 days

Test and reset GFCI per manufacturer’s instructions. Drain and refill

 

 

spa per manufacturer’s instructions.

 

 

 

 

rdr

Every 90 days

Drain and refill spa per manufacturer’s instructions.

 

 

 

 

rCO

Every 180 days

Clean and condition spa cover.

 

 

 

 

rCH

Every 365 days

Install a new filter.

 

 

 

 

Diagnostic Messages

 

 

 

 

 

 

Message

Meaning

 

Action Required

 

 

 

No message

1) Spa temperature is unknown.

1) After pump has been running for 2 minutes

on display

 

 

temperature will be displayed.

 

2) Spa is in Economy or Sleep

2) In Economy or Sleep mode, the pump may be off

 

mode.

 

for hours outside a filter cycle. If you wish to see the

 

 

 

current spa temperature, either switch to Standard

 

 

 

mode or turn Jets1 on for at least two minutes.

 

3) Power has been cut off to the

3) The control panel will be disabled until power

 

spa.

 

returns. Spa settings and time of day will be

 

 

 

preserved for 30 days with a battery back-up.

 

 

 

BUF

Internal problem detected.

Repair required. Contact your dealer or service

 

 

 

organization.

 

 

 

dr

Insufficient water detected in

Check water level in spa. Refill if necessary. Make

 

heater. Spa will be shut down for

sure pumps are been primed and filter cartridges are

 

15 minutes.

 

clean. Press any button to reset or wait 15 minutes

 

 

 

and spa will automatically reset. If message spa does

 

 

 

not reset, call your dealer or service organization.

 

 

 

dry

Insufficient water detected in

Follow directions for dr message and press any button

dY

heater. Spa is shut down.

to reset spa. Spa will not automatically reset when dry

 

(Displays on third occurrence of dr

or dY is displayed.

 

 

 

message.)

 

 

 

 

 

Ec

Indicates heater is in Economy

None.

 

Mode.

 

 

--F or --C

Temperature unknown

 

After the pump has been running for two minutes, the

 

 

 

temperature will be displayed.

 

 

 

HL

A difference in readings between

Make sure spa is filled to proper level and that

HFL

temperature sensors has been

pumps are primed and filter cartridges are clean. If

 

detected indicating a possible water

message does not reset, call your dealer or service

 

flow problem.

 

organization.

 

 

 

IC

Potential freeze condition detected.

No action required. The pumps and the blower will

ICE

 

 

automatically activate regardless of spa status.

 

 

 

 

2011 Portable Spa

www.calspas.com

LTR20111000, Rev. D

Image 20
Contents LTR20111000, Rev. D 9/14/11 Cleaning and Maintenance Using the Entertainment SystemOperating Your Spa AppendixImportant Safety Instructions This FirstRead First!This ForYour New Portable Spa Preparing for Your New Portable SpaPlanning the Best Location Preparing forYour New Portable Spa Preparing a Good FoundationVolt Electrical Installation Gfci and Wiring RequirementsTesting the Gfci Breaker Testing the GfciWires Required Spa Model 240V Gfci and Wiring RequirementsControl System Power Setting Gfci Required Wires Required High Power Configuration Electrical Installation for 11 kW HeaterOFF Position Down On Position Up A10Gfci Wiring Diagram Spa Filling and Powering Up Your Portable SpaYour New Portable Adjust water chemistry Using the control panel Using the bleeder valvePriming the Pump New Portable SpaOperating Your Spa Operating SpaYour5100DV, 6200DV, and 6300DV Electronic Control Operation Initial Start upSwitching Heating Modes Jet Operation One Pump SystemsJet Operation Two and Three Pump Systems Heater LightElectronic Control Operation Auxiliary controls for the 9800 systemSetting the Temperature Lock TimeStandard, Economy, Sleep, and Standby Modes JetsCirculation Pump Clean up Cycle Preset Filter CyclesYour Spa OzoneMessage Frequency Action Required Diagnostic MessagesPeriodic Reminder Messages Stby Message Meaning Action RequiredSnb Sns LED Perimeter Lighting Electrical Power Efficiency JetsOperatingYour Air Venturis Diverter KnobsHydro Streamer Waterfall Waterfalls Adjustable Therapy System Wireless Spa MonitorWater Clarity Water ClarityKey to Clear Water Testing and Adjusting Spa Water Balancing the Total AlkalinityBalancing the pH Balancing the Calcium HardnessUsing Chlorine as a Sanitizer SanitationShocking the Water Chemical SafetyAbout the Pure XL Water Sanitizer Bather Load Filter CleaningOzonator Starting the Spa with Fresh Water Spa capacity gallons Maintenance levelCal Clarity II Bromine Generator Cal Clarity II Settings Testing the WaterAdding BromiCharge to the Water Operating ModesMaintenance Schedule Troubleshooting Water Clarity Problems ClaritySpa Cover Cleaning and MaintenanceRemoving and Reseating the Pillows Cleaning and Replacing the Filter Draining Your Portable SpaFreeze damage is not covered by your warranty Winterizing Cold Climate DrainingVacation Care Continuous water flow and drainageCleaning Your Spa Jet Removal and ReplacementSpa Cover and Pillows Spa ShellUsing the Entertainment System Listening to the RadioPlaying a CD Inserting and Ejecting a DiskUsing the Entertainment Synchronizing the Remote Control with the Docking StationIPod Docking Station SystemReplacement Parts AppendixWaterfalls Air Control ValveWater Diverter Valves DrainsPillows FiltersLED Lights Replacement Cabinet PanelsPure XL UV Water Sanitizer Escape Series CoversDiamond Series Family Series ES848B / ES848L / ES861B 93 x ES861L / ES864B / ES864LFitness Series Platinum SeriesKeeping Fit with your Spa Ultimate Fitness Series Exercise ProgramConnecting the Exercise Equipment Troubleshooting Symptom Possible Causes Possible SolutionsSymptom Water Problems Possible Causes Possible SolutionsSymptom Possible Causes Possible Solutions Pump Problems Pump does not workLimited Warranty Portable SpasManufacturer Warranty Authorized Repairs and ServiceProration of Warranty Acts That Will Void This WarrantyCustomer Service ExclusionsDisclaimers Legal RemediesPortable Spa Portable Spa Warranty Registration Locating the product serial number