Sanyo E11A202U manuals
Computer Equipment > Power Supply
When we buy new device such as Sanyo E11A202U we often through away most of the documentation but the warranty.
Very often issues with Sanyo E11A202U begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Power Supply Sanyo E11A202U is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Power Supply on our side using links below.
47 pages 3.33 Mb
3 Introduction4 1. Safety Precautions5 1. Installation Precautions2. Wiring Precautions 6 3. Operating Precautions7 4. Radio Frequency Interference5. Maintenance and Inspection Precautions 6. Relocation and Transportation Precautions 8 7. Battery Handling Precautions9 2. For Proper Operation10 3.Checking the Contents of the Package11 4. Overview12 5. External Dimensions and Part Names15 6. Installation16 6.4Preparation Before InstallationCAUTION ①Remove the front panel of the UPS cover Remove the insulation tape from the battery connecter of the battery pack side ④ Connect the battery connector ⑤Confirm the "Forced Bypass switch. (Usual inverter side) 17 6.5 Attaching the StandProceed as follows to attach the supplied stand ①Prepare two supplied stand ②Place the UPS in the stand ③The stand is recommended to be fixed to UPS with the screw 18 CAUTION19 7. Wiring21 8. Preparations Before Operation22 9. Operating Procedures26 10.User Settings28 10.2 Setup Menu OperationsSet all menu items with the following procedure This example shows how to set the “UPS operation mode” item to “Economy” ① With MAIN MCCB on the back panel set to “ON”, check that the green INV.ON/STAND BY indicator and the green OUTPUT indicators are not blinking ②Press and hold it for at least 3 seconds ③ Select the menu item to set by using the 5 LEDs surrounded by in the following figure Press and quickly release (within 3 seconds) so that a menu item selection LED Select the value to set by using the 4 LEDs surrounded by 29 11. Maintenance and Inspection30 11.4 Battery Maintenance(1) Battery backup time confirmation Depending on the results of the test, exchange the battery months Estimated battery replacement interval damage may result, so we recommend exchanging batteries early as a preventative and protective step Battery specifications leakage, and heat could result Replace batteries information: HRL1234WF2FR manufactured by CSB BATTERY Co., LTD Battery disposal Please cooperate by recycling when replacing or disposing of used batteries. To 31 11.5 Battery TestProceed as follows to perform a manual battery test ①Press and hold it for 2 seconds The green BATT. TEST indicator starts blinking, and the battery test starts Check the green BATT. TEST indicator for the results of the test After the battery blinking, press The green BATT. TEST indicator goes off and returns to its normal indication ・Mechanical failure ・Switching of Forced Bypass switch ・Setting MAIN MCCB to “OFF” ・Output power overload ・Pressing for 1 second or longer 32 11.6 Battery ExchangeWhen exchanging the batteries,replace the all batteries ③Disconnect the battery connector ④ Pull the battery pack out ⑤Insert the new battery pack so that the connector faces forward ⑥ Connect the battery connector 33 ⑦Confirm the "Forced Bypass switch. (Usual inverter side)⑧Attach the battery cover and fix this cover with 1 screw ⑨ Attach the front panel Reset 34 11.7 Bypass Breaker ResetCAUTION Proceed as follows to reset the bypass breaker ①Stop the inverter by pressing and holding it for 1 second, and then set MAIN MCCB to “OFF” ③Press the bypass breaker on the back panel of the UPS ④ Set MAIN MCCB to “ON”, and then start the UPS by pressing and holding it for 1 second For details about UPS startup, see §9.1 “UPS Startup (Normal Operation)” 35 12. Troubleshooting37 13. Alarm Sounds38 14. Maintenance Bypass Power Supply (Option)39 15. Functional Description44 16. Warranty
Also you can find more Sanyo manuals or manuals for other Computer Equipment.