14Quick Installation Guide

Table 8 Troubleshooting Abnormal Activity on the Module Status LEDs

Module LED Status

Possible Sources of Problem and Steps to Take

 

 

PWR LED lights yellow.

Possible source of problem:

 

Module is not fully inserted.

 

Module has failed.

 

Recommended actions:

 

Verify that the module is fully inserted.

 

Replace the module with a new one.

 

 

INS LED lights yellow.

Possible source of problem:

 

Module is partially inserted.

 

Recommended action:

 

Remove the module and reinsert it.

 

 

ERR LED lights yellow.

Possible source of problem:

 

Module did not successfully complete the

 

 

power-up diagnostics.

 

Recommended actions:

 

Reboot the system.

 

If the ERR LED remains yellow, contact your

 

 

network supplier or 3Com Technical Support.

 

 

E LED (Error - Port Status)

Possible source of problem:

lights yellow.

Module did not successfully complete power-up

 

 

 

diagnostics.

 

An error condition has occurred with the

 

 

associated port, or the port has been disabled

 

 

through the Administration Console or

 

 

WebConsole.

 

Recommended actions:

 

1

Verify that all cables are firmly inserted into the

 

 

system’s affected port and the attached device.

 

2

Check the L LED (Link - Port Status).

 

3

Test for faulty cables.

 

4

If the E LED (Error - Port Status) remains yellow,

 

 

contact your network supplier or 3Com Technical

 

 

Support.

 

 

 

Page 14
Image 14