Maintenance (Continued)
WARNING – Turn air and electrical supplies off and disconnect before beginning maintenance. Failure to comply with this warning could result in severe personal injury or
equipment damage.
Air Line Filter –Figure 4-5
Periodically check the air line filter to drain water and clean as necessary. Do not allow water to go above the filter element.
Circuit Breaker |
|
The case sealer is equipped with a circuit breaker |
|
which trips if the motors are overloaded. Located |
|
inside the electrical control box on the side of the |
|
machine, the circuit breaker has been |
|
2.2 Amps and requires no further maintenance. |
|
WARNING – The following procedure |
|
must be performed by trained service |
|
personnel because of the high voltage |
|
electrical hazard within the control box. |
|
If circuit is overloaded and circuit breaker trips, | Figure |
| |
unplug machine from electrical power: |
|
1.Determine cause of overload and correct.
2.Remove electrical enclosure cover.
3.Press the red "Reset" button and then the green "Start" button.
4.Replace cover.
5.Plug in machine. Wait two minutes.
6.Press machine "On" button, on the side guard, to resume case sealing.
Knife Replacement, Taping Head
See Section II, "Maintenance – Blade (Knife)
Replacement", page 9.
28