Troubleshooting (Continued)
Troubleshooting Guide |
|
|
Problem | Cause | Correction |
|
|
|
Flap kicker kicks at wrong time | Kicker cam improperly set | Reposition kicker cam |
|
| (see page 29) |
| Air cylinder flow controls out of | Readjust flow controls |
| adjustment |
|
|
|
|
Gate does not raise to stop next box
Too much air pressure on gate cylinder lifts box off of gate cam
Incoming boxes not low enough and therefore not actuating cam
Reduce gate air pressure using regulator (see page 31)
Gate retracts too soon/kicker does | The removable portion of the gate | Reinstall removable gate cam |
not kick | cam has been removed and boxes | portion |
| shorter than 12 inches are being |
|
Two boxes are taped together | run |
|
|
|
|
38