Adjustments (Continued)
WARNING – Turn air and electrical supplies off and disconnect before beginning adjustments. Failure to comply with this warning could result in severe personal injury or equipment
damage.
Upper Taping Head Leveling
If the upper taping head is not horizontal, it can be leveled by adjusting the
1.Loosen the five bolts on each side of crossbar shown in Figure
2.Remove access cover as shown in Figure
3.Take measurement from exit end of upper head assembly and front of flap folding ski to machine bed, as shown in Figure
4.Retighten five bolts on each side of crossbar to secure adjustment.
Figure 5-2 – Upper Taping Head Leveling
30