Self-Calibration

Use this function to calibrate the 965DSP-B anytime the outside temperature changes by more than 35°F (20°C). Calibrate the 965DSP-B at the same temperature at which it will be used.

You will see the following screen as soon as you select Self-Calibration from the Toolbox. Test lead connections (open or shorted) are not important during this phase of the calibration.

Short all five leads when prompted, then press [Enter] to continue.

The screen shows ÒSelf-Calibration CompleteÓ when the calibration is done.