GBC |
|
| Operation Manual | ||
|
|
|
|
|
|
SEQUENCE OF OPERATIONS |
| Diagram #1 |
| ||
GBC U.S |
|
|
|
|
|
Effect of Fiber Optics on sequence of operation |
|
|
|
| |
|
|
|
|
| |
Modes | Situation 1 | Situation 2 | Situation 3 | ||
Machine Run Mode | Normal operation | Interrupted optic beam | Optic beam cleared + all safety |
| |
| (No Interruption to any | or opened any safety | circuitries are closed |
| |
| safety circuitry & Fiber | circuitry. |
|
|
|
| optic beam) |
|
|
|
|
| High speed. |
|
|
|
|
|
|
|
|
| |
| Control panel: | Machine stops Instantly. | Machine will remain stationary until | ||
| Forward Speed: Zero to | Use foot pedal to override | run switch is pressed. |
| |
| Max. | @ 3f/m. | Push RUN button switch to run machine |
| |
| Press “Run” push button |
| again (Normal operation) mode. |
| |
| to switch over from foot |
|
|
|
|
| switch to the control |
|
|
|
|
| panel. |
|
|
|
|
|
|
|
|
| |
| Foot switch: | Machine Runs @ | Machine still remains at low voltage | ||
| Forward Speed: Zero to | 3f/m. | speed of 3f/m. |
| |
Forward Mode | Max. | (Automatic override from | Steps required to run at (various speed): |
| |
Note: Press foot pedal | high to low voltage) | The operator will have two choices, |
| ||
Press push button | to change mode and |
|
|
|
|
forward switch | take over from control |
| Choice A: |
| |
| panel at preset speed. |
| 1. Release foot pedal to stop machine. |
| |
|
|
| 2. Press foot pedal again to start |
| |
|
|
| machine at original preset control panel |
| |
|
|
| knob speed (pot). |
| |
|
|
| Choice B: |
| |
|
|
| 1. Press and hold “Run” push button |
| |
|
|
| switch on the control panel while foot is |
| |
|
|
| still on pedal. |
| |
|
|
| 2. Release foot pedal. |
| |
|
|
| 3. Adjust speed using “speed knob” |
| |
|
|
|
|
| |
| Reverse speed: Zero to | Machine stops Instantly. | Machine must not run. It will remain | ||
| Max. | Use Foot pedal to | stationary. |
| |
| Press “Run” push button | override @ 3f/m. | Push RUN button switch to run machine |
| |
| to switch over from Foot |
| again at Normal operation mode. |
| |
| switch to the Control |
|
|
|
|
| panel. |
|
|
|
|
| Reverse speed: Zero to | Machine Runs @ 3f/m. | Machine still remains at low voltage |
| |
| Max. | (Automatic override from | speed of 3f/m. |
| |
Reverse Mode | Note: Press foot pedal | high to low voltage) | Steps required to run at (various speed): |
| |
to change mode and |
| The operator will have two choices, |
| ||
Press Reverse | take over from control |
|
|
|
|
Push button switch. | panel. |
| Choice A: |
| |
|
|
| 1. Release foot pedal to stop machine. |
| |
|
|
| 2. Press foot pedal again to start |
| |
|
|
| machine at original preset control panel |
| |
|
|
| knob speed (pot). |
| |
|
|
| Choice B: |
| |
|
|
| 1. Press and hold “Run” push button |
| |
|
|
| switch on the control panel while foot is |
| |
|
|
| still on pedal. |
| |
|
|
| 2. Release foot pedal. |
| |
|
|
| 3. Adjust speed using “speed knob” |
| |
|
|
|
|
|
|
© 2009 General Binding Corporation an ACCO Brands CO. | Page 16 |