ACCO Brands GBC 2064WF-1 operation manual Sequence Of Operations, Diagram #1

Models: GBC 2064WF-1

1 30
Download 30 pages 20.35 Kb
Page 16
Image 16

GBC 2064WF-1

 

 

Operation Manual

 

 

 

 

 

 

SEQUENCE OF OPERATIONS

 

Diagram #1

 

GBC U.S 2064WF-1

 

 

 

 

 

Effect of Fiber Optics on sequence of operation

 

 

 

 

 

 

 

 

 

Modes

Situation 1

Situation 2

Situation 3

Machine Run Mode

Normal operation

Interrupted optic beam

Optic beam cleared + all safety

 

 

(No Interruption to any

or opened any safety

circuitries are closed

 

 

safety circuitry & Fiber

circuitry.

 

 

 

 

optic beam)

 

 

 

 

 

High speed.

 

 

 

 

 

 

 

 

 

 

Control panel:

Machine stops Instantly.

Machine will remain stationary until

 

Forward Speed: Zero to

Use foot pedal to override

run switch is pressed.

 

 

Max.

@ 3f/m.

Push RUN button switch to run machine

 

 

Press “Run” push button

 

again (Normal operation) mode.

 

 

to switch over from foot

 

 

 

 

 

switch to the control

 

 

 

 

 

panel.

 

 

 

 

 

 

 

 

 

 

Foot switch:

Machine Runs @

Machine still remains at low voltage

 

Forward Speed: Zero to

3f/m.

speed of 3f/m.

 

Forward Mode

Max.

(Automatic override from

Steps required to run at (various speed):

 

Note: Press foot pedal

high to low voltage)

The operator will have two choices,

 

Press push button

to change mode and

 

 

 

 

forward switch

take over from control

 

Choice A:

 

 

panel at preset speed.

 

1. Release foot pedal to stop machine.

 

 

 

 

2. Press foot pedal again to start

 

 

 

 

machine at original preset control panel

 

 

 

 

knob speed (pot).

 

 

 

 

Choice B:

 

 

 

 

1. Press and hold “Run” push button

 

 

 

 

switch on the control panel while foot is

 

 

 

 

still on pedal.

 

 

 

 

2. Release foot pedal.

 

 

 

 

3. Adjust speed using “speed knob”

 

 

 

 

 

 

 

Reverse speed: Zero to

Machine stops Instantly.

Machine must not run. It will remain

 

Max.

Use Foot pedal to

stationary.

 

 

Press “Run” push button

override @ 3f/m.

Push RUN button switch to run machine

 

 

to switch over from Foot

 

again at Normal operation mode.

 

 

switch to the Control

 

 

 

 

 

panel.

 

 

 

 

 

Reverse speed: Zero to

Machine Runs @ 3f/m.

Machine still remains at low voltage

 

 

Max.

(Automatic override from

speed of 3f/m.

 

Reverse Mode

Note: Press foot pedal

high to low voltage)

Steps required to run at (various speed):

 

to change mode and

 

The operator will have two choices,

 

Press Reverse

take over from control

 

 

 

 

Push button switch.

panel.

 

Choice A:

 

 

 

 

1. Release foot pedal to stop machine.

 

 

 

 

2. Press foot pedal again to start

 

 

 

 

machine at original preset control panel

 

 

 

 

knob speed (pot).

 

 

 

 

Choice B:

 

 

 

 

1. Press and hold “Run” push button

 

 

 

 

switch on the control panel while foot is

 

 

 

 

still on pedal.

 

 

 

 

2. Release foot pedal.

 

 

 

 

3. Adjust speed using “speed knob”

 

 

 

 

 

 

 

© 2009 General Binding Corporation an ACCO Brands CO.

Page 16

Page 16
Image 16
ACCO Brands GBC 2064WF-1 operation manual Sequence Of Operations, Diagram #1