C. ELECTRICAL SERVICE SPECIFICATIONS

1.Gas Models

ADG-464 (GAS)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)*

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B.Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3Ø dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

FUSING

CIRCUIT

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

BREAKER

 

 

 

60 Hz

50 Hz

Time Delay

 

208

3/4

107

---

150

150

240

3/4

101

98

150

150

380-400

3/4

---

53

80

90

416

3/4

---

51

60

90

460/480

3/4

51

---

60

90

DEDICATED SPRINKLER SERVICE**

Dryer Nameplate

---

2

3.5

5

*Contact factory for information not listed.

**Minimum wire size is #16 AWG Stranded Type Wire...for individual lengths less than 100 feet.

2.Steam Models

ADS-464 (STEAM)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)*

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B.Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3Ø dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

FUSING

CIRCUIT

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

BREAKER

 

 

 

60 Hz

50 Hz

Time Delay

 

200

3

117

---

150

150

208

3/4

102

---

150

150

240

3/4

96

94

125

150

380-400

3/4

---

51

60

90

416

3/4

---

51

60

90

460/480

3/4

49

---

60

90

DEDICATED SPRINKLER SERVICE**

Dryer Nameplate

---

2

3.5

5

*Contact factory for information not listed.

**Minimum wire size is #16 AWG Stranded Type Wire...for individual lengths less than 100 feet.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.

11

Page 15
Image 15
ADC AD-464 service manual ADG-464 GAS, Electrical Service Specifications