(1)Rotational Sensor Adjustment Distance Adjustment;

Pull the rotational sensor as far away from the basket (tumbler) as possible.

Spin/rotate the basket (tumbler) until the target (target lines up behind one of the basket ribs) is aligned with the rotational sensor.

Mark basket (tumbler) rib with tape.

The rotational sensor has to be adjusted towards the target until there is a 3/16" gap.

Time Adjustment;

• Jog basket (tumbler) for 10-seconds.

• Time the rotational sensor (the time is measured from the last time the target (tapered rib) goes

by the rotational sensor and the indicator light on the sensor goes out.

The measured time has to be 12-seconds.

If an adjustment is required, remove the adjustment cap on the proximity sensor.

Turn potentiometer on the proximity sensor

Retime the sensor.

Adjust as needed.

11)Reinstall the left tilt guard removed in Step #3 (refer to previous page [page 39]).

12)Reinstall the tumbler (basket) section bottom left hand panel removed in Step #2 (refer to previous page [page 39]).