14Check that the motor pulley is properly aligned.

15) Secure the drive motor to the motor mount.

16) Tighten the turnbuckle.

IMPORTANT: DO NOT OVERTIGHTEN TURNBUCKLE.

17)Rewire the new drive motor in the same sequence as the wiring that was removed in Step #2. A wiring diagram is usually affixed to the side of the motor.

18)Reestablish electrical service to the dryer. c. V-Belt Replacement

1)Discontinue electrical service to the dryer.

2)Loosen the turnbuckle a tighten the V-belts.

3)Install the new V-belts.

NOTE: For proper belt replacement, the V-belts should be replaced in matched sets (both belts).

4) Tighten the turnbuckle.

IMPORTANT: DO NOT OVERTIGHTEN V-BELTS.

5)Reestablish electrical service to the dryer.

d. Taper Lock Bushing and Drive Motor Pulley Replacement

1)Discontinue electrical service to the dryer.

2)Loosen the turnbuckle remove the V-belts.

3)Mark the inside of the drive motor shaft.

4)Remove the bolts securing the taper lock busing.

5)Insert bolts into the threaded holes on the motor pulley and tighten evenly for pulley removal.

6)Loosen the set screws on the taper lock bushing and remove the bushing.

7)Measure the mark on the motor drive shaft to the end of the shaft.

8)Install the new drive motor pulley.

9)Align the new taper lock bushing with marks on the shaft and install by tightening the set screws