B. ELECTRICAL REQUIREMENTS and GAS REQUIREMENTS

It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL electrical connections, material, and workmanship must conform to the applicable requirements of the National Electric Code ANSI/NFPA No. 70-LATEST EDITION.

IMPORTANT: Failure to comply with these codes or ordinances and/or the requirements stipulated in this manual can result in personal injury or component failure.

The dryer installation must meet the AMERICAN NATIONAL STANDARD; National Fuel Gas Code ANSI Z223.1-LATEST EDITION, as well as, local codes and ordinances, and must be done by a qualified technician.

NOTE: Undersized gas piping will result in ignition problems and slow drying and can create a safety hazard.

The dryer must be connected to the type of gas (natural or L.P.) indicated on the dryer data label. If this information does not agree with the type of gas available, contact the distributor who sold the dryer or contact the factory.

C. OPERATIONAL SERVICE CHECK PROCEDURE

After performing any service or maintenance function, an operational check should be performed to insure that ALL components are performing properly.

1.Make a complete operational check of ALL the operating controls to insure that the timing is correct, temperature selection switches are functioning properly.

2.Make a complete operational check of ALL safety related circuits, door switches, hi-limit thermostat, air pressure switches, RTD (Resistive Temperature Device) probes, etc.