b.Cable (Wire Rope) Replacement

1)Discontinue electrical service to the dryer.

2)Discontinue the air supply to the dryer.

3)Block the bottom load door in the closed position prior to disassembly of any parts.

IMPORTANT: FAILURE TO BLOCK THE BOTTOM LOAD DOOR SECURELY IN THE CLOSED POSITION MAY RESULT IN PERSONAL INJURY.

4)Loosen the turnbuckle so that the cable becomes slack.

5)Remove the two (2) cable (wire rope) clamps from the wire rope.

6)Loosen the four (4) cable (wire rope) clamp plates from the wire rope.

7)Remove the cable (wire rope).

70

Page 74
Image 74
ADC AD-464 service manual