Local Configuration

LTPS-UM-8013-03

REMOVING D3LX MODULES

D3LX

CO

STATUS

 

FAR

 

 

END

 

DS3

STATUS

 

ENABLE

 

DS3

ONLINE

 

LEC

Optical receptical

Optical connector

Fiber patch cord

D3LX module

Figure 19. Removing a D3LX Module–D3LX CO Shown

Do not look into the ends of any optical fiber or into any plug-in module connector. Exposure to invisible laser radiation may cause permanent eye damage. A meter should be used to verify active fibers.

1For SC-type connectors: pull down on the retaining latch and withdraw the unit halfway out of the chassis while preventing the fiber-optic cord from binding. Release the fiber-optic patch cord from the optical receptacle by gently pulling back on the locking mechanism and remove the cord as shown in Figure 19.

2For FC-type connectors: unscrew the threaded cap counterclockwise and withdraw the unit halfway out of the chassis while preventing the fiber-optic cord from binding.

3Replace the protective cap on the optical connector located on the circuit board.

32

August 30, 2002

D3LX CO and RMT Modules