ADT Security Services 3000 manual 3DJLQJHDWXUH, $ERXW$XWRPDWLF3DJLQJ

Models: 3000

1 56
Download 56 pages 54.39 Kb
Page 26
Image 26
3DJLQJ)HDWXUH
Ex. 1.
Ex. 2.
  ‡   

3DJLQJ)HDWXUH

$ERXW$XWRPDWLF3DJLQJ

Your system may be set up to automatically send alert messages to a pager as certain conditions occur in your system.

The following events can be programmed by your installer to send a message to up to four pagers: arming, disarming, alarms, and trouble conditions.

You can also program the system to send an automatic pager message to alert you in the event that someone has not arrived home (disarmed the system) within a defined period of time (see the Scheduling section for details on programming a “latch key report”).

Your installer programs the pager phone numbers and reporting events.

The pager message consists of a 7-digit system status code that indicates the type of condition that has occurred.

An optional, predefined 16-digit character string can precede the 7-digit system status code; these characters can consist of a PIN no., subscriber account no., or any additional data that you may wish to have sent to the pager.

The pager display format is as follows:

3-digit Event Code

»

Optional 16 digits ￿AAAAAAAAAAAAAAAA BBB CCCC ￿4-digit User or Zone No.

A =

B =

C =

Optional 16-digits for

A 3-digit code that

A 4-digit User or Zone number, depending on the type of

event that has occurred, where:

Account numbers,

describes the event

• alarms and troubles display zone number

PIN numbers, or any

that has occurred

• arming/disarming (opens/closes) display user number

other data;

in your system

programmed by the

(see for event

The first 2 digits are always “00” (e.g., 0004 represents

installer, if required.

codes table below)

zone or user number 4), and, single-digit user or zone

 

 

numbers are always preceded by a zero.

The 3-digit Event Codes (BBB) that can be displayed are:

911 =

811 =

101 =

102 =

 

 

 

 

Alarms.

Troubles.

Open

Close

The 4-digit number

The 4-digit number

(system disarmed).

(system armed).

(CCCC) following this

(CCCC) following this

The 4-digit number

The 4-digit number

code is the zone number

code is the zone number

(CCCC) that follows

(CCCC) that follows

that has caused the

that has caused the

this code is the user

this code is the user

alarm.

trouble.

number that has

number that has armed

 

 

disarmed the system.

the system.

 

 

 

 

Examples of typical 7-digit pager displays follow.

= Reporting of an alarm (911) caused by a fault on zone 4 (0004).

  ‡   = Reporting of a closing–system arming (102)– by user 5 (0005).