SOUND

CAUSE

DISPLAY

 

 

 

LOUD,

FIRE ALARM

FIRE is displayed; zone number of zone in

INTERRUPTED*

 

alarm is displayed. If a fire alarm is manually

Touchpad & Ext.

 

activated, zone number 95 will be displayed.

 

 

 

 

 

LOUD,

BURGLARY/AUDIBLE

ALARM is displayed. Zone number of zone in

CONTINUOUS*

EMERGENCY ALARM

alarm is also displayed.

Touchpad & Ext.

 

 

ONE SHORT BEEP

a. SYSTEM DISARM

a. READY indicator light comes on.

(not repeated)

b. SYSTEM ARMING ATTEMPT

b. Number of the open protection zone displayed.

Touchpad only

WITH AN OPEN ZONE.

 

 

c. BYPASS VERIFY

c. Zone numbers of the bypassed protection

 

 

zones are displayed (one beep is heard for

 

 

each zone displayed). Subsequently, BYPASS

 

 

is displayed.

 

 

 

ONE SHORT BEEP

a. SYSTEM IS IN TEST MODE

a. Opened zone numbers will appear.

(once every 40 secs)

b. LOW BATTERY AT A

b. BAT displayed with zone number of

Touchpad only

TRANSMITTER

transmitter.

TWO SHORT BEEPS

ARM AWAY

AWAY is displayed. Red ARMED indicator is lit.

Touchpad only

 

 

 

 

 

THREE SHORT

a. ARM STAY, NIGHT-STAY, OR

a. STAY or INSTANT is displayed. Red

BEEPS

INSTANT

ARMED indicator is lit.

Touchpad only

 

b. CHIME displayed; zone number of open

 

b. ZONE OPENED WITH

protection zone will be displayed if the []

 

SYSTEM IN CHIME MODE.

key is pressed.

 

 

 

RAPID BEEPING

a. TROUBLE

a. CHECK displayed. Zone number of troubled

Touchpad only

 

protection zone is displayed.

 

b. MEMORY OF ALARM

b. FIRE or ALARM is displayed; zone number

 

 

of zone in alarm is displayed

 

c. SYSTEM LOW BATTERY

c. BAT displayed with no zone ID number.

 

d. EXT. SOUNDER WIRING FAIL

d. CHECK 70 is displayed.

 

 

 

SLOW BEEPING

a. EXIT DELAY WARNING

a. AWAY is displayed.

Touchpad only

b. ENTRY DELAY WARNING

b. Exceeding the entry delay time without

 

 

 

disarming causes alarm.

 

 

 

* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.