6HFXULW\&RGHV $XWKRULW\/HYHOV &RQW

7RDVVLJQ8VHU&RGHVDQG$WWULEXWHV

The following lists the various command strings for adding user codes and attributes. Refer to the User Setup chart at the back of this manual for factory assignments of user attributes and to keep a record of user programming.

NOTE: Partition Programmer code can be used only for user numbers assigned to that programmer’s partition.

Add User Code:

(Users 03/33 are preset to partition programmers, but can be changed.)

Master/Part. Prog.code + [8] + user no. + new user’s code

User 01

= installer

User 03 = partition 1 programmer

User 02

= master

User 33 = partition 2 programmer

The Touchpad beeps once to confirm that new user was added.

Delete User Code:

Master/Part. Prog. code + [8] + [user no.] + [#] [0]

The user code and all attributes* programmed for this user number, including any associated RF keys, are erased from the system. (*except assigned partition)

Authority Level:

Access Group:

User’s Partition:

Factory Assignments: Part. 1 = users 03-32 Part. 2 = users 33-49

RF User Number:

Pager On/Off:

Master/Part. Prog. code + [8] + [user no.] + [#] [1]+ auth. level

Authority Levels (see definitions on previous page):

0

= standard user

3

= duress

1

= arm only

4

= partition programmer

2

= guest

 

 

Master/Part. Prog. Code + [8] + [user no.] + [#] [2]+ group (1-8)

You can assign users to a group, then set an access schedule that defines the times this group of users can operate the system. The system ignores these users outside the scheduled times.

Master Code + [8] + [user no.] + [#] [3]+ partition(s) + [#] (to end)

Use this command to assign the partitions the user can access. Enter partition numbers sequentially, then press [#] to end the entry. Users can operate any combination of partitions desired.

Partition Numbers:

 

 

0

= clears part. 1 and part. 2 assignments

2

= partition 2

1

= partition 1

3

= common partition

Master/Part. Prog. Code + [8] + [user no.] + [#] [4]+ zone no.

Use this command to assign a wireless button device (keyfob) to this user (keyfob must be enrolled in system first; see installer).

Zone number: enter the zone number assigned to a button on the keyfob that will be used for arming/disarming by this user.

Master/Part. Prog. Code + [8] + [user no.] + [#] [5] + 0 or 1

You can program a user so that a message is sent to a pager whenever this code is used to arm or disarm the system. Paging On/Off: 1 = allow paging; 0 = no paging for this user

– 29 –

Page 29
Image 29