ADT Security Services Security Manager 2000 Trouble Conditions, Check and Battery Displays, 29 Ð

Models: Security Manager 2000 Security System

1 44
Download 44 pages 21.74 Kb
Page 29
Image 29

TROUBLE CONDITIONS

"Check" and "Battery" Displays

*Not all systems use wireless sensors.

The word CHECK on the touchpad's display, accompanied by a "beeping" at the touchpad, indicates a trouble condition in the system.

To silence the beeping for these conditions, press any key.

1.A display of "CHECK" and one or more zone numbers indicates that a problem exists with the displayed zone(s) and requires your attention. Determine if the zone(s) displayed are intact and make them so if they are not. If the problem has been corrected, the display can be cleared if you enter the OFF sequence (security code plus OFF key) twice. If the display persists, CALL FOR SERVICE.

Note: A display of CHECK 70 on English Display touchpads indicates that the wiring connection to the external sounder is at fault (opened or shorted), and you should CALL FOR SERVICE. See ÒBELL FAILUREÓ on the next page. A display of CHECK 90 indicates that RF interference may be impeding the operation of wireless sensors* in the system. See ÒRcvr JamÓ on the next page.

2.If there are wireless sensors* in your system, the CHECK condition may also be caused by some change in the environment that prevents the wireless receiver from hearing a particular sensor. CALL FOR SERVICE if this occurs.

IF YOU CANNOT CORRECT A "CHECK" DISPLAY, CALL FOR SERVICE AT ONCE.

TYPICAL "CHECK" DISPLAYS

ÊÊ06 AC

CHECK

CHECK 06

BE DROOM WINDOW

Ê ENGLISH DISPLAY TOUCHPAD

ÊÊÊÊCUSTOM ENGLISH DISPLAY

Ð 29 Ð

Page 29
Image 29
ADT Security Services Security Manager 2000, Security System Trouble Conditions, Check and Battery Displays, 29 Ð