ADTRAN UIG, 61200376L2-31A System Config, T1 Timing Mode, Telnet Access, Telnet User List

Models: 61200376L2-31A UIG

1 72
Download 72 pages 5.86 Kb
Page 24
Image 24
PASSWORD RADIUS

61200375L1-1 TA 850

T1 RCU VoATM UIG/61200376L2-31A Page 24 of 72

System Config

Set up the TA 850 operational configuration from the SYSTEM CONFIG menu. Figure 3 shows the items included in this menu.

Figure 3. System Configuration Menu

>T1 Timing Mode

Selects the timing source for the entire system.

Network

The system’s clock is recovered from the network (T1).

Internal

The system’s clock is generated internally by the TA 850 controller.

>Telnet Access

Sets Telnet access to ON or OFF.

>Telnet User List

Up to four users can be configured for access to the TA 850. Each user can be assigned a security level and time out.

Name

A text string of the user name for this session.

Authen Method

The user can be authenticated in two ways:

The Password field is used to authenticate the user.

The Radius client is used for authenticating the user.

Password

When the authenticating method is password, this text string is used for the password.

TA 850 User Manual

© 2001, ADTRAN, Inc.

Page 24
Image 24
ADTRAN UIG, 61200376L2-31A user manual System Config, T1 Timing Mode, Telnet Access, Telnet User List