61200375L1-1 TA 850 T1 RCU VoATM UIG/61200376L2-31A

Page 55 of 72

7.When the update has successfully completed, TRANSFER COMPLETE appears in the terminal window. If an error occurs during the update, an error message will display in the terminal window. If this occurs, return to Step 3 and attempt the update again. If the same error occurs, contact ADTRAN Technical Support.

8.After the TRANSFER COMPLETE message has been displayed, pull the RCU card again and return dip switch SW1 to the closed or off position. Reinsert the RCU module.

9.Change the emulation software properties to 9600 baud. Disconnect and connect to the unit at this transmit rate and continue configuring the unit as normal.

It is suggested that a factory default be conducted after the unit is updated with new firmware.

Updating Firmware via the Console Menus

1.Using a VT 100 terminal emulation communication software package which contains XMO- DEM protocol support, log in to TA 850.

2.Select SYSTEM UTILITY/UPDATE FIRMWARE.

3.Select XMODEM for TRANSFER METHOD.

4.Press Enter on START TRANSFER <+>.

5.When prompted, press Y to erase flash.

When TA 850 is ready to receive the XMODEM upload, the menu screen will clear and display Transmit Flash . . . download file now. If this does not appear, please review the steps above for possible configuration errors.

6.From the terminal emulation software, begin the XMODEM upload by using the appropriate command sequence. (If necessary, refer to terminal emulation software documentation for help. Also, when specifying the filename, ensure that the file transferred is the one pro- vided by ADTRAN. Otherwise, the update will not complete successfully.)

Because XMODEM data is being transferred in-band through the menu interface, the VT 100 menus of TA 850 will be inoperable from the CRAFT port.

© 2001, ADTRAN, Inc.

TA 850 User Manual

Page 55
Image 55
ADTRAN 61200376L2-31A, UIG user manual Updating Firmware via the Console Menus