61200375L1-1 TA 850 T1 RCU VoATM UIG/61200376L2-31A
Page 45 of 72
Each log (PPP log, Connection log, and Network log) contains the following elements.
Active
When set to YES (def), PPP events below or equal the log level are logged into the log.
Wrap
When set to YES (def), new PPP events will overwrite old PPP events when the log is full. All logging will stop when the log is full and set to NO.
Level
In order to log events, they must be at or below this level. Range is 0 to 6. The default is 3.
View
This menu displays the log list. The fields are as follows:
DATE/TIME | Date and time event occurred. |
LEVEL | Level associated with this event |
MESSAGE | Text message for this event. If message is too |
| long to fit on the line, another event appears |
| below it continuing the message. |
Clear
This clears the log when activated.
© 2001, ADTRAN, Inc. | TA 850 User Manual |