Figure 4.2-2 Screen saver setting

When the screen saver setting is done, tap “OK” to accept the settings just made, “Cancel” to discard or “Save” to permanently save the settings to the registry.

Notice:

Please be careful when selecting “Save”. This

 

command will overwrite all registry data—not only the

 

screen saving settings.

4.2.3Watchdog timer

It is important in industrial applications that the control systems are rarely down, or are capable of self-reset if they are halted somehow. The watchdog timer is therefore used in the TPC-1260 to provide automatic reset. There is a timer inside the watchdog timer. The TPC- 1260 should clear the timer within a pre-set time interval periodically. If the timer is not cleared, the timer would assume the system to be halted and generate a reset.

The watchdog timer in the TPC-1260 provides a fixed time interval: 1.6

seconds. As mentioned in the section 4.2.2: when the system boots, there is an icon “S” on the status bar. Tap this icon by a stylus for the setting window.

Select whichever time interval required, and tap one of the buttons: “OK”, “Cancel” or “Save”.

Notice:

Please be careful before selecting “Save”. This

 

command will overwrite all registry data—not only the

 

watchdog timer settings.

2 8 TPC-1260 User's Manual

Page 36
Image 36
Advantech TPC-1260 manual Watchdog timer, Screen saver setting