Agilent Technologies 6633B, 6634B, 66332A Troubleshooting, 1Sheet 6. FS Indicated but Fuse OK

Models: 6632B 6633B 66332A 6634B

1 83
Download 83 pages 60.43 Kb
Page 30
Image 30
Figure 3-1 Sheet 6. FS Indicated but Fuse OK

3 - Troubleshooting

Program output on, voltage and current full scale then check output voltage

FS Prot off and Output OK?

 

 

Calibrate unit

Yes

 

 

 

 

No

Disable the protection feature by simultaneously pressing the 0 and 9 keys, press the ^ key until the display reads "No Protect Off", press the Up Arrow to display "No Protect On" then press enter

Output V >

 

 

 

Go to "Troubleshooting

programmed

 

Yes

 

High Output Voltage"

 

value?

 

 

 

(sheet 12)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

Check FUSE signal U305B-7 (approx.

+2.8V with 20V output)

 

 

 

 

Troubleshoot Fuse

FUSE signal OK?

 

 

 

divider and amplifier

 

No

 

 

 

circuit (R393/394,

 

 

 

 

 

 

 

 

U305)

Yes

Problem may be defective A2 or one of the voltages to A2 (Vmon, Imon_H, Imon_L, Imon_P) > its' bias voltage +5Vs

Figure 3-1 Sheet 6. FS Indicated but Fuse OK

30

Page 30
Image 30
Agilent Technologies 6633B, 6634B, 66332A, 6632B service manual Troubleshooting, 1Sheet 6. FS Indicated but Fuse OK