Agilent Technologies 6633B, 6634B, 66332A Troubleshooting, 1Sheet 2. Main Flowchart continued

Models: 6632B 6633B 66332A 6634B

1 83
Download 83 pages 60.43 Kb
Page 26
Image 26
Figure 3-1 Sheet 2. Main Flowchart (continued)

3 - Troubleshooting

Continued from sheet 1

Program Voltage and Current full scale, enable output with no load. Measure Voltage at output terminals.

Display and

 

 

 

Voltage close

measured

 

No

 

 

 

to programmed

voltage OK?

 

 

 

 

 

 

value?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If output is OK but

 

 

 

 

 

 

 

 

 

 

meter wrong, replace

 

 

Output Voltage

 

 

 

 

A2. If both are off,

No

 

 

No

 

 

 

near zero?

 

 

 

check gain of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Monitor

 

 

 

 

 

 

 

 

 

 

Amplifier A1U315B

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

Load output to put unit into CC and measure output current with extrenal amp meter

Display and measured current OK?

Yes

Calibrate Voltage

Current close

No to programmed value?

Yes

Go to

"Troubleshooting No Output Voltage"

(sheet 7)

Current > prog

NoManual background and unit not in CC?

Yes

 

 

If output is OK but

 

 

meter wrong, replace

 

 

A2. If in CC but both

 

 

are off, check gain of

 

 

Current Monitor

 

 

Amplifiers and

 

 

Monitor Resistor

No

 

 

R403/473 values. If

 

 

 

 

the current is lower

 

 

than programmed

 

 

and UNReg is

 

 

displayed, check

Program OV below output voltage

OV Trips?

Yes

NoManual background

Calibrate Current

Go to

"Troubleshooting Unit Does not OV” (sheet 11)

Go to "Troubleshooting No Current limit" (sheet 10)

A1Q307 and Output

Stage

Program OV to maximum and reset protection

Go to sheet 3

Figure 3-1 Sheet 2. Main Flowchart (continued)

26

Page 26
Image 26
Agilent Technologies 6633B, 6634B, 66332A, 6632B service manual Troubleshooting, 1Sheet 2. Main Flowchart continued