Agilent Technologies 6634B, 66332A, 6633B Troubleshooting, 1Sheet 8. No Output Voltage continued

Models: 6632B 6633B 66332A 6634B

1 83
Download 83 pages 60.43 Kb
Page 32
Image 32
Figure 3-1 Sheet 8. No Output Voltage (continued)

3 - Troubleshooting

Continued from sheet 7

Q302 base -5V

?

 

 

Check C330, R333,

No

 

 

R346, and Q302

 

 

 

 

 

Yes

Q303 base >1.2V

 

 

Check +Rail and

 

Yes

(meas. from +Out)

 

Output Stage

 

 

?

No

>1V across R323

 

No

 

?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

Q307 collector to

 

 

 

No

 

emitter

 

 

 

 

4V?

 

 

Check Q301, Q305 circuits

Check Q302, Q307, R324 and R326

Yes

Check C331, C333,

C339 and Q306

circuits

Figure 3-1 Sheet 8. No Output Voltage (continued)

32

Page 32
Image 32
Agilent Technologies 6634B, 66332A, 6633B, 6632B service manual Troubleshooting, 1Sheet 8. No Output Voltage continued