Table 1-2a. Performance Specifications for Series 665xA1

Parameter

 

 

Agilent Model Number

 

 

 

 

6651A

6652A

6653A

 

6654A

6655A

Output Ratings

 

 

 

 

 

 

 

Voltage:

 

0 - 8 V

0 - 20 V

0- 35 V

 

0 - 60 V

0 - 120 V

Current:@ 40°C

 

0 - 50 A

0 - 25 A

0 - 15 A

 

0 - 9 A

0 - 4 A

Current:@ 50°C

 

0 - 45 A

0 - 22.5 A

0 - 13.5 A

 

0 - 8.1 A

0 - 3.6 A

Current:@ 55°C

 

0 - 42.5 A

0 - 21.3 A

0 - 12.8 A

 

0 - 7.7 A

0 -3.4 A

 

 

 

 

 

 

 

Programming Accuracy (@ 25 ± 5 °C)

 

 

 

 

 

 

Voltage: 2

0.06% +

5 mV

10 mV

15 mV

 

26 mV

51 mV

Current:

0.l5 % +

60 mA

25 mA

13 mA

 

8 mA

4 mA

 

 

 

 

 

 

Ripple & Noise (from 20 Hz to 20 MHz with outputs ungrounded, or with either output terminal grounded)

 

Constant Voltage:

rms

300 ∝V

300 ∝V

400 ∝V

 

500 ∝V

700 ∝V

Constant Voltage:

p-p

3 mV

3 mV

4 mV

 

5 mV

7 mV

Constant Current:

rms

25 mA

10 mA

5 mA

 

3 mA

2 mA

 

 

 

 

 

 

 

Readback Accuracy (from front panel or over GPIB with respect to actual output @ 25 ± 5 °C)

 

 

Voltage: 2

0.07% +

6 mV

15 mV

25 mV

 

40 mV

80 mV

+Current

0.15% +

67 mA

26 mA

15 mA

 

7 mA

3 mA

-Current

0.35% +

100 mA

44 mA

24 mA

 

15 mA

7 mA

 

 

 

 

 

 

 

Load Regulation (change in output voltage

or current for any load change within ratings)

 

 

Voltage:

 

1 mV

2 mV

3 mV

 

4 mV

5 mV

Current:

 

2 mA

1 mA

0.5 mA

 

0.5 mA

0.5 mA

 

 

 

 

 

 

 

Line Regulation (change in output voltage

or current for any line change within ratings

 

 

Voltage:

 

0.5 mV

0.5 mV

1 mV

 

1 mV

2 mV

Current:

 

2 mA

1 mA

0.75 mA

 

0.5 mA

0.5 mA

 

 

 

 

 

 

 

 

Transient Response Time (for the output voltage to recover to its previous level (within 0.1% of the rated voltage or 20 mV, whichever is greater) following any step change in load current up to 50% of the rated current.

 

< 100 ∝s

AC Input Ratings (selectable via internal

switching - see Appendix C)

Nominal line voltage:

100, 120, 220, 240 Vac (-13%, +6 %)

 

Frequency:

230 Vac3 (-10%, +10%)

50/60 Hz

 

Output Terminal Isolation

±240 Vdc (maximum, from chassis ground)

Notes: 1For Supplemental Characteristics, see Table 1-2b.

2Specification may degrade slightly when unit is subjected to an RF field ≥ 3V/meter. 3For 230Vac operation, unit is internally set to 240Vac

General Information 21