192
S:\agilent\8920\8920b\PRGGUIDE\BOOK\SECTIONS\efpkc.sec
Equivalent Front-Panel Key Commands
INCR×10

The INCR×10 Data Function increases the increment setting by a factor of 10

(new increment setting = current increment se tting × 10).

NOTE: Integer-only fields (such as Intensity and Print Adrs) have a fixed
increment of 1, and cannot be changed.
Syntax
:INCRement:MULTiply
Example
OUTPUT 714;"RFG:FREQ:INCR:MULT"
If the RF Generator’s frequency increment is 1 MHz, this command increases increment value from 1 MHz to 10 MHz.
INCR÷10

The INCR÷10 Data Function reduces the increment setting by a factor of 10 (new

increment setting = current increment setting ÷ 10).

NOTE: Integer-only fields (such as Intensity and Print Adrs) have a fixed
increment of 1, and cannot be changed.
Syntax
:INCRement:DIVide
Example
OUTPUT 714;"RFG:FREQ:INCR:DIV"
If the RF Generator’s frequency increment is 10 MHz, this command reduces the increment value from 10 MHz to 1 MHz.