GLOBAL
Page 254 CD3000XL OperatorÕs Manual
Pressing F7 ( ) will display this screen:
The parameters on this page are used to set SCSI ID’s. The most important parameters you
need to know about are and .
SCSI allows up to 8 devices to be on the buss and these each have a unique number 0-7 (it’s
similar to the concept of MIDI channels). In order for one SCSI device to ‘talk’ to a hard drive,
their SCSI ID’s must match. The field sets the SCSI ID for the sampler’s
SCSI interface and hence the SCSI ID of the drive you will record to and playback from. The
default setting in the field is 5. This parameter must be set to match that of
the drive. For example, if your external drive is 1, this parameter must be set to 1. You may, if
you wish, have several drives connected and each of these must have different SCSI ID’s.
Each one can be selected by changing the ID number in the field.
The field allows you to switch between the different MO formats
of disk. There are two - 512Bytes per sector and 1kByte per sector. Both offer the same
storage, they just have different sector sizes. The CD3000XL can use both and this is selected
in this field. The default is 512b.
The field sets the CD3000XL’s SCSI ID (as distinct from the sampler’s SCSI
interface’s ID) and is used when communicating between samplers or computer editors over
SCSI.
The soft keys on these pages are:
Takes you to the DD TAKES page.
This takes you to the SONG mode where you may compile takes for sequential
playback or MIDI triggering.
This takes you to the play pages where you may play takes.
This takes you to the take editing display.
Takes you to the record setup page.
Takes you directly to the record page for recording new takes.
Takes you to the HARD DISK CONTROL page (see above).
This allows you to delete a take off disk.
At any time, you may play the selected take by holding down the ENT/PLAY key. The take will
only play for as long as you hold the key down.