Installation

7

1

2

3

6.After completing the dryer check, reinstall service door on top of meter case.

NOTE: When reinstalling service door, front of door must be inserted at about a 45° angle in order to engage notched tabs with internal rib at top of meter case.

5 4

5

6

6

COMET, TOKETTE AND

DRY1967K

GREENWALD AND

MONARCH COIN SLIDES

ESD COIN SLIDES

 

DRY1967K

1501796 Slide Extension Modifier

2Hole “A”

3Hole “B”

4506114 Slide Extension

503950 Phillips Head Screws and Lockwashers

6Coin Slide

7501086 Self-Tapping Screw

Figure 4

4.Reinstall coin slide in dryer meter case. Refer to Figure 5.

NOTE: The position of the accumulator arm is between the push and pull extension of the slide extension.

5.CHECK DRYER OPERATION – Connect electrical power to dryer. Place required number of coins in coin slide. Push slide in and observe through service door opening in meter case if the slide extension is contacting the accumulator actuator arm and moving arm back with slide travel.

When slide is pushed all the way in (accumulator arm will be rotated to the back) and slide is retracted, the accumulator actuator arm should remain back until the slide extension is moved forward and again contacts the actuator arm to return the arm to the starting forward position. Refer to Figure 5.

1

4

2

3

DRY1968K

1Accumulator Actuator Arm

2501796 Slide Extension Modifier (If required)

3Coin Slide

4506114 Slide Extension

Figure 5

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

510969