Installation Instructions

WARNING

Clearance of tumbler cabinet from combustible construction must be a minimum of 12 inches (30.5 cm) at top.

W647

NOTE: Shaded areas indicate adjacent structure.

0 in Clearance Permitted for First

4 in (10.2 cm)

Clearance

0 in to

Combustible

Material

12 in (30.5 cm)

Minimum Clearance

Guard

0 in Clearance

Clearances shown are minimum to nearest combustible material. 0 in (0 cm) Minimum clearance to combustible material.

24 in (61.0 cm) Minimum recommended for service access.

0 in Clearance Permitted 24 in

(61.0 cm) Recommended for

Maintenance Purposes

TMB2157N

Tumbler exhaust duct must be smooth inside and be sized based on the following air flow data: 450 CFM maximum and 350 CFM minimum at .3 W.C. (See information on VENTING in this manual for duct dimensions).

For proper combustion, supply a two square foot (.19 sq. meter) opening for outside makeup air.

Figure 5

IMPORTANT: Do not lift under the belt guard or tip the unit. Serious drive train damage will occur.

Leveling the Drying Tumbler

Each tumbler should be leveled within 1/8 inch (3

mm)from front to rear and 1/8 inch (3 mm) from side to side. Check front to rear level by rotating the clothes cylinder until one rib is at the bottom, then place a level on the rib. Check side to side level by placing a level across the center of the top panel.

IMPORTANT: An unleveled tumbler can cause rapid bearing wear, internal misalignment, scraping, noise, and possible clothes damage.

M412060

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT