Installation Instructions
WARNING
Clearance of tumbler cabinet from combustible construction must be a minimum of 12 inches (30.5 cm) at top.
W647
NOTE: Shaded areas indicate adjacent structure.
0 in Clearance Permitted for First
4 in (10.2 cm)
Clearance
0 in to
Combustible
Material
12 in (30.5 cm)
Minimum Clearance
Guard
0 in Clearance
Clearances shown are minimum to nearest combustible material. 0 in (0 cm) Minimum clearance to combustible material.
24 in (61.0 cm) Minimum recommended for service access.
0 in Clearance Permitted 24 in
(61.0 cm) Recommended for
Maintenance Purposes
TMB2157N
Tumbler exhaust duct must be smooth inside and be sized based on the following air flow data: 450 CFM maximum and 350 CFM minimum at .3 W.C. (See information on VENTING in this manual for duct dimensions).
For proper combustion, supply a two square foot (.19 sq. meter) opening for outside makeup air.
Figure 5
IMPORTANT: Do not lift under the belt guard or tip the unit. Serious drive train damage will occur.
Leveling the Drying TumblerEach tumbler should be leveled within 1/8 inch (3
mm)from front to rear and 1/8 inch (3 mm) from side to side. Check front to rear level by rotating the clothes cylinder until one rib is at the bottom, then place a level on the rib. Check side to side level by placing a level across the center of the top panel.
IMPORTANT: An unleveled tumbler can cause rapid bearing wear, internal misalignment, scraping, noise, and possible clothes damage.
M412060 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 17 |