1.Install a fused disconnect switch, or a circuit breaker, as close to the tumbler as possible. If more than one stacked tumbler is being installed, provide a disconnect switch or circuit breaker for each. This will make it possible to individually disconnect stacked tumblers for maintenance purposes.
2.Connect the
(L1 and L2 or L1 and N). If the electrical service is 120 Volt, connect the neutral wire to NEUTRAL. The ground wire must be connected to the green ground screw located in the junction box. Refer to Figure 10.
3.Reinstall cover on the junction box.
Installation Instructions
Grounding InstructionsThis drying tumbler must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electronic shock by providing a path of least resistance for electric current. This dryer must be connected to a grounded metal, permanent wiring system or to the ground screw (located in the junction box).
WARNING
To reduce the risk of fire and electric shock, check with a qualified serviceperson for proper grounding procedures. Improper connection of the equipment grounding conductor may result in a risk of electric shock.
W068R1
IEI
Board
| Terminal | |
| Jumper | |
| Block | |
Terminal | Ground | |
Screw | ||
Block | ||
|
TMB2161N
Figure 10