1.Turn gas
2.Start tumbler in drying cycle. Spark igniter will begin sparking as the gas valve simultaneously opens. The gas burner is ignited by the sparking igniter. The igniter will then shut off. Burner will remain on for as long as the temperature control calls for heat.
3.Opening the loading door will extinguish burner flames. Closing loading door and restarting tumbler should cause gas to be
4.If gas does not light, open and close loading door again and restart the ignition cycle.
Installation Instructions
IMPORTANT: The Instant Electronic Ignition system will attempt to light the gas by sparking for approximately 15 seconds. If gas does not ignite within 15 seconds, the Instant Electronic Ignition control will go into safety lockout (if this occurs, the red light on the IEI board will be illuminated). The valve will not open until the Instant Electronic Ignition control is reset. Reset by opening and closing the loading door.
If condition persists, check that the gas
5.To remove tumbler from service, disconnect electrical service and turn gas
On
Position
Off
Position
Gas
Line
TMB2162N
Figure 12
M412060 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 25 |