Instructions for Lighting and Shutting Down Instant Electronic Ignition System

1.Turn gas shut-off valve to “on” position (handle parallel with gas line). Refer to Figure 12.

2.Start tumbler in drying cycle. Spark igniter will begin sparking as the gas valve simultaneously opens. The gas burner is ignited by the sparking igniter. The igniter will then shut off. Burner will remain on for as long as the temperature control calls for heat.

3.Opening the loading door will extinguish burner flames. Closing loading door and restarting tumbler should cause gas to be re-ignited.

4.If gas does not light, open and close loading door again and restart the ignition cycle.

Installation Instructions

IMPORTANT: The Instant Electronic Ignition system will attempt to light the gas by sparking for approximately 15 seconds. If gas does not ignite within 15 seconds, the Instant Electronic Ignition control will go into safety lockout (if this occurs, the red light on the IEI board will be illuminated). The valve will not open until the Instant Electronic Ignition control is reset. Reset by opening and closing the loading door.

If condition persists, check that the gas shut-off valve is open and that gas service is properly connected. If condition still persists, remove tumbler from service.

5.To remove tumbler from service, disconnect electrical service and turn gas shut-off valve to “off” position (handle at right angle to gas line). Refer to Figure 12.

On

Position

Off

Position

Gas

Line

TMB2162N

Figure 12

M412060

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

25