Every Six Months
Lint Removal and Cylinder Belt Inspection
WARNING
To reduce the risk of serious injury, disconnect power to the tumbler before performing this operation.
W657
Drive System
1.Remove belt guard cover.
2.Clean the lint and any other foreign materials from the air vents located on the front and back of the drive motor. The drive motor is air cooled and if the air vents become clogged, the motor will overheat and the internal thermal overload protector will cycle off.
3.Reinstall belt guard cover.
Front Panel
1.Remove front panel by removing lint drawer and loading door. Remove fastening screws for front panel, disconnect control housing, terminal blocks.
2.Pull front panel out. Remove any lint that has accumulated in the corner of the inside. Use a vacuum where possible or a small brush.
3.The
Preventive Maintenance Instructions
4.Inspect the belt tensioning idler assembly. The idler arm should move freely (with considerable
5.Clean lint off any of the idler assembly parts.
6.Reassemble the front panel by lifting and placing the panel at its edge resting on the machine front.
7.Reach in through door opening, and connect the terminal blocks to each control housing.
8.Push the front panel into place and line up holes.
9.Insert corner screws first and then remaining screws. Tighten all screws.
10.Reinstall lint drawer, pressing it firmly against the front panel and locking it.
11.Reinstall loading door.
Overall Check
Check the tumbler over thoroughly for loose nuts, bolts and screws and for loose gas and electrical connections.
WARNING
To reduce the risk of fire or electric shock, electrical connections such as electric service and grounding connections should be examined for proper torque a week after initial installation, again after a month of operation and thereafter every six months.