Installation

Step 4: (Gravity Drain Models Only) Connect Drain Outlet to Drain System

Remove drain fitting and hose clamp from accessories bag, and clamp fitting onto drain outlet.

Connect the drain fitting to a vented drain system using a flexible connection (obtain locally). The drain system must be vented to prevent an air lock or siphoning.

IMPORTANT: Increasing the drain hose length, installing elbows, or causing bends will decrease drain flow rates and increase drain times, impairing machine performance.

2

1

SWD745N

SWD745N

1Drain Trough

2Drain Outlet

Figure 8

Step 5: (Gas Dryer Only) Connect Gas Supply Pipe

For further assistance, refer to section on Gas Requirements.

1.Make certain dryer is equipped for use with the type of gas in laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8 inch N.P.T. gas connection.

2.Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe threads when removing the cap.

3.Connect to gas supply pipe using a new flexible stainless steel connector.

4.Tighten all connections securely. Turn on gas and check all pipe connections (internal and external) for gas leaks with a non-corrosive leak detection fluid.

5.For L.P. (Liquefied Petroleum) gas connection, refer to section on Gas Requirements.

20

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

801539