It is important that the laundry room has adequate
Do
●Supply adequate air for ventilating air, drying air and gas dryer combustion air.
NOTE: Each dryer pocket must have 40 square inches (260 cm2) of unobstructed flow of
●Energy efficient buildings with low air infiltration rates should be equipped with an air exchanger that can accommodate on demand
Don’t
●Draw
●Draw
Installation
Exhaust Direction
The dryer can be exhausted to the outdoors through the back, left or right of the dryer. EXCEPTION: Gas dryers cannot be vented out the left side because of the burner housing.
Unit is shipped from factory ready for rear exhaust; no kits required.
Exhausting the dryer through sides can be accomplished by installing a Directional Exhaust Kit 528P3 available as optional equipment at extra cost.
1
2
H297I
528P3 DIRECTIONAL EXHAUST KIT
H297I
1Weather Hood with Hinged Dampers
2Rigid or Flexible Metal Duct
Figure 36
801539 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 43 |