Installation

Step 11: Plug In the Washer and Dryer

Refer to sections on Electrical Requirements and connect the washer and dryer to an electrical power source.

D254I

WASHER

Plug cord into separately fused 15 Amp circuit.

D254I

Figure 17

ELECTRIC DRYER

Connect to 30 Amp circuit.

D275I

Figure 18

D254I

GAS DRYER

Plug cord into separately fused 15 Amp circuit.

D254I

Figure 19

Step 12: Check Installation

Refer to Installer Checklist on the back cover and make sure that unit is installed correctly.

Moving Unit to a New Location

To prevent damage while moving the unit, the shipping materials MUST BE reinstalled.

Reinstallation of Shipping Materials

Disconnect unit from electrical supply.

Remove front access panel by removing two screws.

Place the shock sleeves on all four shock absorbers. Refer to Figure 20.

Insert hooked end of shipping brace into the open slot of the motor mount. Attach with bolts and lockwashers. Refer to Figure 20.

Reinstall front access panel.

1

4

2

3

H336I

1Shock Sleeves

2Motor Mount

3Bolts and Lockwashers

4Hooked End of Shipping Brace

Figure 20

Refer to step 8 for proper procedures whenever the unit is moved.

26

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

801539