Installation
Pre-Installation Inspection
Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.
Remove the crate and protective cover as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.
IMPORTANT: Warranty is void unless tumbler is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed herein, and with applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all
Material Required (Obtain Locally)
All Models | One fused disconnect switch or circuit | |
breaker. | ||
| ||
|
| |
Gas Models | One gas | |
line to each tumbler. | ||
|
| |
Steam | One steam | |
Models | service line to be connected upstream of | |
| solenoid steam valve. | |
| Steam | |
| return line. | |
| Flexible steam hoses with a 125 psig | |
| (pounds per square inch gauge) | |
| (8.78 kg/sq. cm) working pressure for | |
| connecting steam coils. Refer to | |
| Figure 15 for sizing and connection | |
| configurations. | |
| Steam trap for steam coil outlet to | |
| condensate return line. | |
| Optional – Vacuum breaker for | |
| condensate return line. | |
|
| |
| Table 1 |
Location Requirements
The tumbler must be installed on a level floor. Floor covering materials such as carpeting or tile should be removed.
To assure compliance, consult local building code requirements. The tumbler must not be installed or stored in an area where it will be exposed to water and/or weather.
IMPORTANT: DO NOT block the airflow at the rear of the tumbler with laundry or other articles. Doing so would prevent adequate air supply to the combustion chamber of the tumbler.
A typical tumbler enclosure is shown in Figure 1. Note that the enclosure touches the tumbler top and side panels. Also, note the minimum and maximum dimensions. Local codes and ordinances must be complied with.
WARNING
To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.
W055
IMPORTANT: Install tumblers with sufficient clearance for servicing and operation. Refer to Figure 1.
IMPORTANT: Keep tumbler area clear and free from combustible materials, gasoline and other flammable vapors and liquids.