Electrical Requirements

For T45 Gas Models (For Total Machine):

 

Terminal Block

 

Recommended Fuse

 

Recommended

Serial Plate

Current

Breaker

Minimum

Voltage

Connections

(Amps)

or Breaker Rating

Poles

Conductor Size

Required

(Amps)

 

 

 

(AWG [mm2])

 

 

 

 

 

208–240V/60Hz/1ph

L1, L2, Neutral and ground

12.0

15

2

14 (2.08)

 

 

 

 

 

 

200–208V/60Hz/3ph

L1, L2, L3 and ground

9.6

15

3

14 (2.08)

 

 

 

 

 

 

240V/60Hz/3ph

L1, L2, L3 and ground

9.6

15

3

14 (2.08)

 

 

 

 

 

 

200V/50Hz/1ph

L1, Neutral and ground

11.2

15

1

14 (2.08)

 

 

 

 

 

 

230-240V/50Hz/1ph

L1, Neutral and ground

10.8

15

1

14 (2.08)

 

 

 

 

 

 

Table 11

70304601

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

41