Installation

Table 3 describes the different gases that are available in different CE countries, and how the machines need to be configured to operate with those gases. In the CE, there are Natural Gas configurations that do not allow for machine regulation, and L.P. Gas configurations that must be regulated. For L.P. Gas, third family B/P at 50 mbar, order regulated Natural Gas machines and convert according to Table 3.

Basic Configuration

1.Determine the necessary conversion operations to convert from the factory-supplied configuration to the desired configuration.

2.Perform the conversions required so the machine is properly configured for the desired country and gas (refer to Specific Conversion Procedures section):

How to Convert Gas Valve from Regulated to Unregulated

NOTE: Conversion from regulated to unregulated is only needed when regulated tumblers were ordered, but unregulated tumblers were needed, or if the gas supply type is changed at a later date.

How to Change Burner Orifice Size

How to Adjust Gas Valve Governor/Regulator

How to Change Regulator Spring, DE/AT Only

3.If applicable, peel off the appropriate country sticker (included with machine) and apply it to the serial plate over the existing country information.

4.If applicable, peel off the appropriate conversion sticker (included with machine) and apply it to the data plate over the “ADJUSTED FOR ______

GAS: ______” information.

5.Commission tumbler for use.

WARNING

When converting the tumbler to a different gas or pressure, first verify that the supply inlet pressure is equipped with a pressure regulator (located ahead of the tumbler) that will maintain the gas supply at the inlet pressure specified.

W430

SPECIFIED

LOCAL INLET

PRESSURE

2

3 1

T103K

1Gas Shut-Off Valve (Ahead of pressure tap)

2Pressure Tap

3Gas Shut-Off Valve (Shown in closed position)

Figure 6

20