Electrical Requirements
Electrical Requirements for Electric Models
Refer to Table 12.
NOTE: Minimum wire sizes are obtained from Canadian Electrical Code for 75°C Conductors and are intended for use as a guideline only. Electrical connections should be made only by a qualified electrical contractor in accordance with all applicable local and national requirements.
For 21 kW T30 Electric Models:
NOTE: Electrical specifications below are subject to change without notice. Always refer to product serial plate for most current specifications of product being installed.
NOTE: Connect to individual branch circuit.
NOTE: 3 Phase Only – Each tumbler must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single phasing” and causing premature failure of the motor(s).
| Terminal Block |
| Recommended |
| Recommended | |
Serial Plate | Current | Breaker | Minimum | |||
Connections | Breaker Rating | |||||
Voltage | (Amps) | Poles | Conductor Size | |||
Required | (Amps) | |||||
|
|
| [AWG (mm2)] | |||
L1, L2, L3, | 62** | 80 | 3 | 4 (21.2) | ||
and ground |
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
| |
200V/50Hz/3ph* | L1, L2, L3, | 60** | 80 | 3 | 4 (21.2) | |
and ground |
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
| |
L1, L2, L3, | 55** | 70 | 3 | 4 (21.2) | ||
and ground |
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
| |
240V/60Hz/3ph* | L1, L2, L3, | 54** | 70 | 3 | 4 (21.2) | |
and ground |
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
| |
380V/50 or 60Hz/3ph* | L1, L2, L3, | 33** | 45 | 3 | 8 (8.37) | |
and ground |
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
| |
L1, L2, L3, | 31** | 40 | 3 | 8 (8.37) | ||
and ground |
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
| |
L1, L2, L3, | 27** | 35 | 3 | 8 (8.37) | ||
and ground |
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
|
*These serial plate voltages are only options available on the T30 electric models. Current (Amp) is for one pocket only.
**Per heater on T30 electric models, each has two heaters.
Table 12
42 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70304601 |