Electrical Requirements
Conversion Instructions
If serial plate voltage is: |
|
|
|
| Tumbler can be converted to the following voltages: | ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
120 Volt/60 Hertz/ |
|
| |||||||||||||||||||||||||
1 Phase | 3W&G |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
2W&G | 1. | Prior to connecting service, locate the black/red wire which runs between | |||||||||||||||||||||||||
(T30 Models Only) |
| terminal block and the motor relay or contactor. Refer to figure below. | |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 120 V~ LOCATION | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (AS RECEIVED) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| L1 |
|
|
|
|
|
| 208 or 240 V~ | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| 120 V |
|
|
|
|
|
|
|
|
|
|
|
|
| LOCATION | ||||
|
|
|
|
|
|
|
|
| - |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (AS CONVERTED) | |
|
|
| 208 OR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| L2 |
|
|
|
|
|
|
| ||||
|
|
|
| 240 V- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
| 120 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| V- |
|
|
|
|
|
|
|
|
|
| TO MOTOR RELAY | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OR CONTACTOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| L3 |
|
|
| BLK/RED | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TERMINAL BLOCK |
| T381I | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 2. | Disconnect the black/red lead from L1 of the terminal block and connect to | |||||||||||||||||||||||||
|
| L2 of the terminal block. Repeat steps 1 and 2 for upper and lower junction | |||||||||||||||||||||||||
|
| box areas. |
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
| 3. | Sign and date conversion sticker located on back of tumbler. | |||||||||||||||||||||||||
| 4. | Follow the instructions covered in Connecting Electrical Service section. | |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
240 Volt/60 Hertz/ |
|
| |||||||||||||||||||||||||
3 Phase | 3W&G |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
3W&G | 1. | Prior to connecting electric service, locate transformer configuration jumper | |||||||||||||||||||||||||
|
| in junction box area. |
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
| 2. | Remove the 240 Volt jumper and replace it with the 208 Volt jumper located | |||||||||||||||||||||||||
|
| in the literature packet in cylinder. |
|
| |||||||||||||||||||||||
| 3. | Repeat steps 1 and 2 for each upper and lower unit. | |||||||||||||||||||||||||
| 4. | Sign and date conversion sticker located on back of tumbler. | |||||||||||||||||||||||||
| 5. | Follow the instructions covered in Connecting Electrical Service section. | |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
38 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70304601 |