Electrical Requirements

Electrical Requirements for Gas and Steam Models

Refer to Table 10 and Table 11.

NOTE: Minimum wire sizes are obtained from Canadian Electrical Code for 75°C Conductors and are intended for use as a guideline only. Electrical connections should be made only by a qualified electrical contractor in accordance with all applicable local and national requirements.

For T30 Gas and Steam Models

(For Total Machine):

NOTE: Electrical specifications below are subject to change without notice. Always refer to product serial plate for most current specifications of product being installed.

NOTE: Use copper conductors only.

NOTE: 3 Phase Only – Each tumbler must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single phasing” and causing premature failure of the motor(s).

 

Terminal Block

 

Recommended

 

Recommended

Serial Plate

Current

Fuse or

Breaker

Minimum

Connections

Voltage

(Amps)

Breaker Rating

Poles

Conductor Size

Required

 

 

(Amps)

 

[AWG (mm2)]

120V/60 Hz/1ph

L1, Neutral,

16.0

20

1

12 (3.31)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208-240V/60Hz/

L1, L2, Neutral,

8.0

10

2

14 (2.08)

1ph

and ground

 

 

 

 

 

 

 

 

 

 

100V/60Hz/1ph

L1, Neutral,

22.0

30

1

10 (5.26)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200-220V/60Hz/

L1, Neutral,

11.6

15

1

14 (2.08)

1ph

and ground

 

 

 

 

 

 

 

 

 

 

100V/50Hz/1ph

L1, Neutral,

24.2

35

1

8 (8.37)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200V/50Hz/1ph

L1, Neutral,

15.0

20

1

12 (3.31)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/

L1, Neutral,

15.0

20

1

12 (3.31)

1ph

and ground

 

 

 

 

 

 

 

 

 

 

200-208V/60Hz/

L1, L2, L3,

6.4

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

240V/60Hz/3ph

L1, L2, L3,

6.4

10*

3

14 (2.08)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200V/50Hz/3ph

L1, L2, L3,

5.8

10*

3

14 (2.08)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/

L1, L2, L3,

7.0

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

380V/50 or 60Hz/

L1, L2, L3,

3.0

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

400-415V/50Hz/

L1, L2, L3,

3.2

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

460-480V/60Hz/

L1, L2, L3,

3.3

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

*3 Phase machines should not have fuses, breakers only.