9.Wipe out the cylinder using an all-purpose cleaner or detergent and water solution. Refer to Figure 5.

T452I

T452I

Figure 5

If the tumbler does not meet ANY of the listed requirements, remove tumbler from use. Refer to Removing Tumbler from Service section

Required for CE Models Only

Once machine is installed, please be sure to complete the following items:

Review and verify machine operation with customer.

Leave all literature and a signed Declaration of Conformity with customer.

Review machine warranty information with customer.

Apply warning sticker on front panel of machine, in language appropriate to country of sale (included in literature packet).

Installation

Installing CE Gas Drying Tumblers

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumbler before servicing.

Close gas shut-off valve to gas tumbler before servicing.

Close steam valve to steam tumbler before servicing.

Never start the tumbler with any guards/ panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

W002

General Information

This information is to be used when installing gas tumblers in countries, and/or on gases, different than the machine’s factory configuration. Tumblers are supplied from the factory for operation on Natural Gas 1000 Btu/cu ft. (8914 kcal/m3), or L.P. Gas 2500 Btu/ cu ft. (22,250 kcal/m3) in the countries of GB/IE/PT/ ES/IT/GR/LU/CH. To install machines in any other country, or on any other gas, requires some level of modification.

Burner orifices, stickers, block-open kits, regulator springs and other parts needed for conversions are to be ordered separately.

Models are built in two different configurations:

Regulated Natural Gas – Burner orifice is sized for Natural Gas, second family, group H (E) at 20 mbar inlet pressure. Regulator/governor is operational. Gas valve CAN be field-converted to a non-regulating type.

Unregulated L.P. (Liquefied Petroleum) Gas – Burner orifice is sized for L.P., third family, group 3+ at 28.37 mbar inlet pressure. Regulator/ governor is blocked open. Gas valve CANNOT be field-converted to a regulating type.

Serial plates supplied from the factory are configured for the countries of GB/IE/PT/ES/IT/GR/LU/CH. These instructions pertain to the situations when the country of use or gas supply is different than that on the serial plate.

70304601