Gas Requirements
High Altitude Burner Orifice Sizing
For proper operation at altitudes above 2000 feet (610 meters), the gas burner orifice size must be reduced to ensure complete combustion. Refer to Table 8.
For CE models, consult local gas supplier.
|
| Altitude |
|
|
| Burner Orifice |
| New Rate | ||
Model | Gas |
|
|
|
|
|
|
|
|
|
Feet | Meters | No. | Inches | mm | Quantity | Part | (Btu/hr.)* | |||
|
| Number | ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
T30 | Natural Gas | 22 | 0.1570 | 4.0 |
| M402996 | 134,320 | |||
|
|
|
|
|
|
|
|
|
| |
|
| 24 | 0.1520 | 3.9 |
| M402980 | 122,640 | |||
|
|
|
|
|
|
|
|
|
| |
|
| 26 | 0.1470 | 3.7 |
| M401000 | 110,960 | |||
|
|
|
|
|
|
|
|
|
| |
|
| 28 | 0.1405 | 3.6 | 2 | M401014 | 99,280 | |||
|
|
|
|
|
|
|
|
|
| |
| L.P. Gas | 42 | 0.0935 | 2.4 |
| M403017 | 134,320 | |||
|
|
|
|
|
|
|
|
|
| |
|
| 43 | 0.0890 | 2.3 |
| M406184 | 110,960 | |||
|
|
|
|
|
|
|
|
|
| |
|
| 44 | 0.0860 | 2.2 |
| M401011 | 99,280 | |||
|
|
|
|
|
|
|
|
|
|
|
T45 | Natural Gas | 2001 – 4000 | 610 | – 1220 | 15 | 0.1800 | 4.6 |
| M411511 | 183,000 |
|
|
|
|
|
|
|
|
|
|
|
|
| 4001 – 6000 | 1221 | – 1830 | 17 | 0.1730 | 4.4 |
| M411374 | 168,400 |
|
|
|
|
|
|
|
|
|
|
|
|
| 6001 – 8000 | 1831 | – 2440 | 18 | 0.1695 | 4.3 |
| M402988 | 155,000 |
|
|
|
|
|
|
|
|
|
|
|
|
| 8001 – 10000 | 2441 | – 3050 | 20 | 0.1610 | 4.1 | 2 | M401002 | 142,600 |
|
|
|
|
|
|
|
|
|
|
|
| L.P. Gas | 2001 – 4000 | 610 | – 1220 | 36 | 0.1065 | 2.7 |
| M402487 | 183,000 |
|
|
|
|
|
|
|
|
|
|
|
|
| 4001 – 6000 | 1221 | – 1830 | 37 | 0.1040 | 2.6 |
| M411375 | 168,400 |
|
|
|
|
|
|
|
|
|
|
|
|
| 6001 – 8000 | 1831 | – 2440 | 38 | 0.1015 | 2.6 |
| M411376 | 155,000 |
|
|
|
|
|
|
|
|
|
|
|
|
| 8001 – 10000 | 2441 | – 3050 | 40 | 0.0980 | 2.5 |
| M406361 | 142,600 |
|
|
|
|
|
|
|
|
|
|
|
* Btu/hr. derate of 4% per 1000 feet (305 meters) of altitude.
Table 8
34 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70304601 |